2005
DOI: 10.1109/tasc.2005.849982
|View full text |Cite
|
Sign up to set email alerts
|

Compact Readout Electronics for 62-Channel DROS Magnetocardiogram System

Abstract: Compact and low-cost SQUID electronics to operate double relaxation oscillation SQUIDs (DROSs) has been constructed for detecting magnetocardiogram (MCG) fields. SQUID electronics consists of low-noise preamplifier with a white noise of 0.6 nV Hz, flux-locked loop (FLL) circuit with auto-reset, and interface circuit to control FLL using 3 digital lines from a computer. The automatic control software adjusts SQUID parameters to the optimum operating condition within 15 seconds for 62 channels. Outputs of FLL ci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…An Agilent 35670A spectrum analyzer was used for noise evaluation. Note that for each measurement, the sensor signal was amplified using a specially designed low-noise preamplifier [ 46 ]. In this experimental environment, the amplifier exhibited a white noise level of 1 with a gain of 60 dB.…”
Section: Methodsmentioning
confidence: 99%
“…An Agilent 35670A spectrum analyzer was used for noise evaluation. Note that for each measurement, the sensor signal was amplified using a specially designed low-noise preamplifier [ 46 ]. In this experimental environment, the amplifier exhibited a white noise level of 1 with a gain of 60 dB.…”
Section: Methodsmentioning
confidence: 99%
“…For noise characterization, the sensor current was applied along the magnetic easy axis using a Keithley 2400 Current Source Meter. The sensor signal was amplified by a custom-made low-noise preamplifier [ 58 ] and sampled by a 16-bit ADC model (35670A Keysight FFT Dynamic signal analyzer) with a sampling rate of 512 Hz. Temperature dependence of noise measurements was performed in both CC and CV modes at different sensing currents.…”
Section: Methodsmentioning
confidence: 99%
“…The digital pulses were transmitted through fibre-optic cables. Each FLL PCB has a size of 45 mm × 95 mm; the FLL circuits and digital interface circuits are assembled as shown in figure 2 [14]. Figure 3 shows a block diagram of the measurement system.…”
Section: Readout and Control Electronics For Squid Operationmentioning