Abstract: A compact focusing crystal spectrometer based on the von Hamos scheme is described. Cylindrically curved mica and graphite crystals with a radius of curvature of Rϭ20 mm are used in the spectrometer. A front illuminated charge-coupled device ͑CCD͒ linear array detector makes this spectrometer useful for real-time spectroscopy of laser-produced plasma x-ray sources within the wavelength range of ϭ1.8-10 Å. Calibration of crystals and the CCD linear array makes it possible to measure absolute photon fluxes. X-ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(27 citation statements)
references
References 22 publications
(15 reference statements)
0
27
0
Order By: Relevance
“…This has been especially true after the development and commercial availability of CCD-based x-ray detectors allowed the highly productive implementation of von Hamos style, wavelength dispersive spectrometers. [65][66][67][68][69][70] Laboratory-based work using SBCA's is less common, but includes comparative studies of x-ray emission from direct x-ray excitation as opposed to from Kcapture. 83,88 …”
Section: Iib X-ray Emission Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…This has been especially true after the development and commercial availability of CCD-based x-ray detectors allowed the highly productive implementation of von Hamos style, wavelength dispersive spectrometers. [65][66][67][68][69][70] Laboratory-based work using SBCA's is less common, but includes comparative studies of x-ray emission from direct x-ray excitation as opposed to from Kcapture. 83,88 …”
Section: Iib X-ray Emission Spectroscopymentioning
confidence: 99%
“…By contrast, and with only rare exceptions in the last 20 years, 'routine' hard x-ray XAFS [49][50][51][52][53][54][55][56][57][58][59][60][61][62][63][64] and high-resolution XES [65][66][67][68][69][70] can only be performed at the synchrotron light sources.…”
Section: Introductionmentioning
confidence: 99%
“…The spectrometer geometry allows recording a wide energy range x-ray emission spectrum at a single excitation energy and has found a variety of applications in combination with lab, synchrotron, and XFEL sources. 30,[40][41][42][43][44] Thanks to the dispersive-type of diffraction, the spectrometer geometry provides the possibility of a single-shot measurement with a total energy bandwidth ranging from a few tens to a few hundreds of eV. The development of innovative and compact von Hamos spectrometers has also benefited from the parallel advances of position-sensitive detectors.…”
Section: Introductionmentioning
confidence: 99%
“…The contrast ratio was equal to [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]. These values are the low limit ofthe measuring values when the experimental errors are defined by the unreproducibility of laser pulse energy from shot to shot.…”
Section: Methodsmentioning
confidence: 99%