2014
DOI: 10.3390/en7042498
|View full text |Cite
|
Sign up to set email alerts
|

Compact Design of 10 kW Proton Exchange Membrane Fuel Cell Stack Systems with Microcontroller Units

Abstract: Abstract:In this study, fuel, oxidant supply and cooling systems with microcontroller units (MCU) are developed in a compact design to fit two 5 kW proton exchange membrane fuel cell (PEMFC) stacks. At the initial stage, the testing facility of the system has a large volume (2.0 m × 2.0 m × 1.5 m) with a longer pipeline and excessive control sensors for safe testing. After recognizing the performance and stability of stack, the system is redesigned to fit in a limited space (0.4 m × 0.5 m × 0.8 m). Furthermore… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 18 publications
(20 reference statements)
0
3
0
Order By: Relevance
“…Some electronic devices, in this case certain producers of DC/DC, are sensitive to brief power outages of this type However, there is a lack of data and understanding regarding ways to improve the performance of single MEA cells and to optimise the short-circuiting strategy for fuel cell stacks constructed from smaller modules. The performance of the SCU also has a considerable impact on the integration of other devices, such as DC/DC, into a hybrid power source [31].…”
Section: Analysis Of Hydrogen Fuel Consumption During V-type Pemfc Stmentioning
confidence: 99%
See 2 more Smart Citations
“…Some electronic devices, in this case certain producers of DC/DC, are sensitive to brief power outages of this type However, there is a lack of data and understanding regarding ways to improve the performance of single MEA cells and to optimise the short-circuiting strategy for fuel cell stacks constructed from smaller modules. The performance of the SCU also has a considerable impact on the integration of other devices, such as DC/DC, into a hybrid power source [31].…”
Section: Analysis Of Hydrogen Fuel Consumption During V-type Pemfc Stmentioning
confidence: 99%
“…This value is close to that indicated in all data existing in the literature regarding an air-cooled PEMFC stack. According to paper [31], the hydrogen utilisation coefficient was calculated according to the following formula…”
Section: Analysis Of Hydrogen Fuel Consumption During V-type Pemfc Stmentioning
confidence: 99%
See 1 more Smart Citation