2013 IEEE 14th International Symposium on Computational Intelligence and Informatics (CINTI) 2013
DOI: 10.1109/cinti.2013.6705214
|View full text |Cite
|
Sign up to set email alerts
|

Communication protocols in substation automation and IEC 61850 based proposal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 4 publications
0
14
0
1
Order By: Relevance
“…The average and standard deviation are 2100 and 160 µs, respectively. As a result, and as shown by (2), the DDS delay time is 1100 µs. Table 1 summarizes the results for these two study cases.…”
Section: Case (2) Dds Publish-subscribe Over the Network Layermentioning
confidence: 77%
“…The average and standard deviation are 2100 and 160 µs, respectively. As a result, and as shown by (2), the DDS delay time is 1100 µs. Table 1 summarizes the results for these two study cases.…”
Section: Case (2) Dds Publish-subscribe Over the Network Layermentioning
confidence: 77%
“…The main contributions of the numerical relays are the accurate sensitivity, digital showing the instantaneous measurements, fault recorder function and the protection IEDs has the function to be used with IEC 61850 protocol for sending and receiving data. In order to provide distance protection between two substations, IEC 61850 protocol can uses with the protection numerical relay for accelerating the protection scheme depending on the fiber optic cable to be linked between the two remote and local protection IEDs [50]. The timing requirement of the protection scheme to operate during a fault being very critical, such as interlocking and blocking, the protection IEDs must act quickly within 4-ms, which can cover by the IEC 61850 stander [51].…”
Section: Iec 61850 For Aided Trip Schemementioning
confidence: 99%
“…This facility important at the line fault near one side which the remote IED protection relay calculate the fault impedance in the zone two boundaries, which will send the trip order after 200 ms to 500 ms delay time. IEC 61850 communication scheme will accelerate the isolation fault to be an instantaneous trip in both sides by adjusting the zone 1 to transport the signal to the remote IED which configure to trip at carrier receive with starting zone 2 distance protection [50]. Fig.…”
Section: Iec 61850 For Aided Trip Schemementioning
confidence: 99%
“…Um protocolo SGé definido como um barramento que define métodos padronizados de comunicações lógicas entre entre IEDs em subestações elétricas, equipamentos de processo primário, dispositivos secundários e Sistemas de Supervisão e Aquisição de Dados (SCADA, do inglês Supervisory Control and Data Acquisition), que coexistem em um mesmo ecossistema do operador de energia. Os principais protocolos legados SG para automação de subestações são o DNP3 [IEEE 2012] e o IEC 61850 [IEC61850 2020], eles estão presente em praticamente todos os sistemas de automação e controle de subestações [Horalek et al 2013] [Ortega et al 2016 A garantia de plena interoperabilidade entre IEDs legados e os demais sistemas de energia se apresenta como desafio constante ao longo de todos esses anos de vida da SG. No escopo dessa pesquisa, partimos do pressuposto que os IEDs legados precisam ser incorporados a IoT para que possam convergir em uma SG-Cloud-IoT, de modo que sejam acessados de forma ubíqua para coleta e análise de dados.…”
Section: Introductionunclassified