2018
DOI: 10.1149/2.0031815jes
|View full text |Cite
|
Sign up to set email alerts
|

Communication—Contribution of Catalyst Layer Proton Transport Resistance to Voltage Loss in Polymer Electrolyte Water Electrolyzers

Abstract: Mass transport losses (η mt x ) play a significant role at high current densities in polymer electrolyte water electrolyzers (PEWEs). Previous work has shown that η mt x depends on the porous transport layer (PTL) structure, although a clear correlation between the material morphology and η mt x has not been established. In this work, we experimentally determine the overpotential η H + C La associated with the proton transport in the anodic catalyst layer by measuring the ionic resistance in the catalyst layer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
57
1
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 52 publications
(63 citation statements)
references
References 14 publications
(32 reference statements)
0
57
1
2
Order By: Relevance
“…The total η mtx of the non-contaminated electrolyzer was subsequently corrected for the R H + CLa to obtain η rest , as the R H + CLc is negligible in this case. 53,55 The analysis of mass transport losses based on the corrections yields a R H + CLc of a contaminated electrolyzer to increase up to 520 ± 32 mOhm cm 2 , which is almost 3 times higher compared to the value obtained from the H 2 /N 2 measurements ( Figure S5).…”
Section: Resultsmentioning
confidence: 89%
See 2 more Smart Citations
“…The total η mtx of the non-contaminated electrolyzer was subsequently corrected for the R H + CLa to obtain η rest , as the R H + CLc is negligible in this case. 53,55 The analysis of mass transport losses based on the corrections yields a R H + CLc of a contaminated electrolyzer to increase up to 520 ± 32 mOhm cm 2 , which is almost 3 times higher compared to the value obtained from the H 2 /N 2 measurements ( Figure S5).…”
Section: Resultsmentioning
confidence: 89%
“…Ionic and total mass transport resistance.-The cell voltage is iR-corrected ( Figure 5b) and further analyzed using the Tafel model in order to distinguish between the kinetic and mass transport losses. The mass-transport losses (η mtx ) in PEWE consist of contributions from the anode (η H + CLa ) and cathode (η H + CLc ) catalyst layer proton transport resistances, [53][54][55][56] and the contributions from the other cell components (η rest ): [11][12][13]49…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The lower operational limit (LOL) for the turndown ratio is set by the current density value for a concentration of 2% hydrogen in oxygen and can be determined by solving [8]. The experimentally obtained values for the LOL and the values obtained by solving [8] with the linear regression parameters from Table SI at differential pressures and membrane types are listed in Table SI. The lower values for the LOL from fitting than from the experiment could be due to neglecting the permeation of oxygen to the anode side in [6].…”
Section: Supplementary Material: Pt-doped Thin Membranes For Hydrogenmentioning
confidence: 99%
“…Hydrogen permeation rate from anode to cathode side in a PEWE cell using pristine NR212 (N212, black), and a Pt doped NR212 obtained by reduction with hydrogen (Pt-N212, green) at ambient cathodic pressures, 5 bara and 10 bara, respectively, and 60 o C (anode: 1 bara). The lines represent a linear fit through the points calculated by [8]. The linear regression parameters are listed in Table SI.…”
Section: N212mentioning
confidence: 99%