2022
DOI: 10.1016/j.rser.2021.111971
|View full text |Cite
|
Sign up to set email alerts
|

Common-mode voltage mitigation in multiphase electric motor drive systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 127 publications
0
10
0
Order By: Relevance
“…The final block diagram of the induction motor drive is completed by integrating the subsystems in which the torque-current feedback loop and induced emf feedback loop are overlapped. Block-diagram reduction techniques are used to overcome this overlap in which the inner current loop is made independent of the motor mechanical transfer function, and this method offers a simpler construction of the current controller [29][30][31][32].…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation
“…The final block diagram of the induction motor drive is completed by integrating the subsystems in which the torque-current feedback loop and induced emf feedback loop are overlapped. Block-diagram reduction techniques are used to overcome this overlap in which the inner current loop is made independent of the motor mechanical transfer function, and this method offers a simpler construction of the current controller [29][30][31][32].…”
Section: Figurementioning
confidence: 99%
“…The stator voltage equations can be reformed for the vector control scheme by using the following relationship in Eqs. ( 28 (31) where σ is the leakage coefficient. The flux-producing element of the stator current is fixed in steady state condition, which is the d axis stator current in the synchronous frames.…”
Section: Vector-controlled Induction Motormentioning
confidence: 99%
“…The ant colony optimization algorithm, a particular number of ants are randomly placed in N cities and the pheromone of every route is meant to be equal at this moment [19], [20]. Ants pick their next city based on the pheromone concentration of each route as they go across the countryside.…”
Section: Ant Colony Optimization That Been Adjustment 321 the Fundame...mentioning
confidence: 99%
“…Several research studies have been conducted to reduce or eliminate CMV. These studies include the use of advanced inverter topologies [13]- [15], filters [16] or specific modulation techniques [17], [18]. Some modulation techniques allow for reducing CMV without employing filters or advanced converter topologies, thus reducing costs and design time.…”
Section: Introductionmentioning
confidence: 99%