Commissural Alignment After Balloon-Expandable Transcatheter Aortic Valve Replacement Is Associated With Improved Hemodynamic Outcomes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 19 publications
0
11
0
1
Order By: Relevance
“…Higher rates of central leaks for misaligned valves were confirmed at 3 month follow-up [ 25 ]. The CMA-related leaflet distortion shown in Bailey’s models could support this observation, though it has not been confirmed by other studies [ 26 ].…”
Section: Possible Implications Of Commissural Alignment Beyond Corona...mentioning
confidence: 59%
See 1 more Smart Citation
“…Higher rates of central leaks for misaligned valves were confirmed at 3 month follow-up [ 25 ]. The CMA-related leaflet distortion shown in Bailey’s models could support this observation, though it has not been confirmed by other studies [ 26 ].…”
Section: Possible Implications Of Commissural Alignment Beyond Corona...mentioning
confidence: 59%
“…Recently, the impact of commissural alignment on valve hemodynamic and related clinical outcomes has been retrospectively analyzed in a population of 324 consecutive patients treated with balloon-expandable THVs [ 26 ]. No overt effect of misalignment on transvalvular gradients was noted at discharge.…”
Section: Possible Implications Of Commissural Alignment Beyond Corona...mentioning
confidence: 99%
“…Early immobile leaflets are presumed to generate turbulent flow eddies across the prosthesis leaflets causing increased shear stress and premature deterioration of the valve, as well facilitating clot formation that may further impair leaflet mobility [ 2 , 14 ]. Increase of valve gradients immediately following SAVI have also been shown to be a predictor of BAV thrombosis, whereas following TAVI commissural misalignment was a reported predictor in some studies [ 15 , 16 ]. The impact of subclinical BAV thrombosis on postprocedural outcomes, valve durability and function, as well as the risk of mortality and stroke remains uncertain [ 6 ].…”
Section: Discussionmentioning
confidence: 99%
“…Another bench study with the Acurate neo THV in a valve-in-valve configuration demonstrated that THV commissural misalignment was associated with a higher incidence of paravalvular leakage and impaired leaflet motion due to interaction with the leaflets of the surgical valve ( 25 ). Recently, an association between severe commissural misalignment and an early increase in gradient following an S3 THV implant have been suggested ( 26 ). Data from the RESOLVE registry among 324 patients showed that significant commissural misalignment defined as commissural offset > 30° was observed in 52.8% of patients but was not associated with significant paravalvular leakage, intravalvular leakage, increase in the mean gradient >20 mmHg, or HALT initially.…”
Section: Clinical Impact Of Commissural Misalignmentmentioning
confidence: 99%