2008
DOI: 10.1016/j.ijrobp.2008.05.060
|View full text |Cite
|
Sign up to set email alerts
|

Commissioning and Quality Assurance of RapidArc Radiotherapy Delivery System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

10
238
2
9

Year Published

2010
2010
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 247 publications
(261 citation statements)
references
References 19 publications
10
238
2
9
Order By: Relevance
“…Our Dynalog file analysis is in line with Ling et al, ( 29 ) demonstrating that during the dynamic arc delivery the deviation between the actual and intended leaf positions increases with leaf speed. In the dynamic arc mode, the beam cannot be held off if the leaves did not reach their intended positions because that would involve stopping and starting the gantry rotation.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…Our Dynalog file analysis is in line with Ling et al, ( 29 ) demonstrating that during the dynamic arc delivery the deviation between the actual and intended leaf positions increases with leaf speed. In the dynamic arc mode, the beam cannot be held off if the leaves did not reach their intended positions because that would involve stopping and starting the gantry rotation.…”
Section: Discussionsupporting
confidence: 90%
“…( 28 , 29 ) They were recorded for a number of SmartArc plans and analyzed with Varian Argus v. 4.7 software. The available data include the average RMS deviations across all leaves, the maximum RMS deviation in that cohort, the 95% range on the error histogram, the maximum leaf deviation, and the leaf speed.…”
Section: Methodsmentioning
confidence: 99%
“…It is also ideal to relate MLC positioning accuracy to the dose delivery errors in the patient, so that decisions on MLC performance can be based off metrics that are clinically relevant for the patient. This is not currently possibly using the widely accepted test MLC patterns for arc therapy MLC QA 4 , 5 . In this paper the method presented has the ability to directly measure MLC positions during clinical VMAT deliveries.…”
Section: Discussionmentioning
confidence: 99%
“…These three dynamic components (i.e., MLC, gantry angle, and dose rate) must remain synchronized throughout the treatment in order to deliver the intended dose to the planning target volume (PTV) and organs at risk (OAR). Due to this high level of complexity, there is a need for comprehensive and informative quality assurance (QA) techniques 4 , 5 …”
Section: Introductionmentioning
confidence: 99%
“…Commissioning and QA procedures for VMAT can be conducted using electronic portal imaging device (EPID). One of the most commonly used QA procedures for Varian linacs (Varian Medical Systems, Palo Alto, CA, USA) are the Ling tests, which rely solely on integrated EPID images 9. These tests, like most common QA methodologies, focus on the accuracy of the dose rate and MLC control systems rather than the gantry angle and gantry speed aspects of the VMAT delivery.…”
Section: Introductionmentioning
confidence: 99%