“…The PDD exhibits almost the same behavior for all detectors unless a little discrepancy is observed for ISD, especially in water depths larger than 15 mm. This effect can be strongly reduced by necessary corrections of the reference detector . Moreover, some discrepancies that appear in small fields and nearby water surfaces can be due to the proper centering of the reference dosimeter.…”
Section: Discussionmentioning
confidence: 99%
“…The PDD exhibits almost the same behavior for all detectors unless a little discrepancy is observed for ISD, especially in water depths larger than 15 mm. This effect can be strongly reduced by necessary corrections of the reference detector . Moreover, some discrepancies that appear in small fields and nearby water surfaces can be due to the proper centering of the reference dosimeter.…”
Section: Discussionmentioning
confidence: 99%
“…Melalui rentang keseimbangan partikel bermuatan pada bidang lateral, r LCPE (dalam mm) dapat ditentukan hubungan antara lapangan radiasi dan dimensi minimal detektor yang digunakan agar syarat rentang keseimbangan partikel bermuatan pada bidang lateral terhadap sumbu utama berkas radiasi foton dipenuhi yang bergantung pada energi berkas radiasi. Hubungan ini dinyatakan dengan Persamaan 1 atau Persamaan 2 (IAEA, 2017) (Das & Francescon, 2018).…”
Section: Kesetimbangan Partikel Bermuatan DI Lateral (Lateral Charge unclassified
“…Later TRS‐483 10 provided the code of practice for small field dosimetry along with methods and correction factors to determine field output factors (FOF) for various detectors and square field sizes. When field sizes are reduced below around 15 or 20 mm, the uncertainty in FOF data increases as the curve is very steep 10,11 . The uncertainty of measurement is highly dependent on the definition of the field size that could potentially increase the uncertainty in the small field dosimetry due to the sensitivity to measurement errors.…”
Section: Introductionmentioning
confidence: 99%