2005
DOI: 10.1039/b512077b
|View full text |Cite
|
Sign up to set email alerts
|

Comment on “AC frequency characteristics of coplanar impedance sensors as design parameters” by Jongin Hong, Dae Sung Yoon, Sung Kwan Kim, Tae Song Kim, Sanghyo Kim, Eugene Y. Pak and Kwangsoo No, Lab Chip, 2005, 5, 270

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 4 publications
0
11
0
Order By: Relevance
“…The cultures were kept in a 10% CO 2 atmosphere at 37 uC. The medium, cFAD (a 3 : 1 mixture of the DulbeccoVogt modification of Eagle's medium and Ham's F12 medium; Gibco BRL) supplemented with 10% fetal calf serum (Hyclone Laboratories Inc.) and 10 ng ml 21 human recombinant EGF as described previously, 23,24 was changed every 2 days. Reference cultures were cultured on commercial polystyrene culture dishes (Falcon 35-3001, Becton-Dickinson France SA).…”
Section: Cell Culturementioning
confidence: 99%
See 1 more Smart Citation
“…The cultures were kept in a 10% CO 2 atmosphere at 37 uC. The medium, cFAD (a 3 : 1 mixture of the DulbeccoVogt modification of Eagle's medium and Ham's F12 medium; Gibco BRL) supplemented with 10% fetal calf serum (Hyclone Laboratories Inc.) and 10 ng ml 21 human recombinant EGF as described previously, 23,24 was changed every 2 days. Reference cultures were cultured on commercial polystyrene culture dishes (Falcon 35-3001, Becton-Dickinson France SA).…”
Section: Cell Culturementioning
confidence: 99%
“…23,24 They were cultured on a feeder layer of lethally irradiated mouse embryonic 3T3 fibroblasts. The cultures were kept in a 10% CO 2 atmosphere at 37 uC.…”
Section: Cell Culturementioning
confidence: 99%
“…Fabrication of the devices from an anisotropic silicon master enables deep, high-throughput features in the main channel without any degradation in performance of the concentrator since its design features are channel height independent. The electrodes used as impedance sensors in our design are coplanar and rectangular as oftentimes employed in microfluidic applications (Hong et al 2005;Linderholm and Renaud 2005). The sensing electrodes in our microfluidic chips are passivated with oxide (SiO 2 ) to avoid the unwanted effects of a direct metal-electrolyte interface at the electrode surface and to maintain system stability for extended periods of time (Sanchis et al 2007).…”
Section: Introductionmentioning
confidence: 99%
“…Suehiro et al showed that impedance measurements can be effectively used to detect cells (Suehiro et al 2003a) when coupled with electroporation of cells (Suehiro et al 2003c) or with an antibody-antigen reaction (Suehiro et al 2003b). In these devices, interdigitated metallic electrodes are used to DEP trap particles, which are initially collected on the surface of the electrode (Gomez-Sjoberg et al 2005;Liu et al 2007). Formations of linear clusters (a.k.a.…”
Section: Introductionmentioning
confidence: 99%
“…Such closed-form analytical expressions that determine electrodynamic characteristics of coplanar electrode structures can be derived from conformal mapping methods [13]. For instance, these have been applied to determine the cell constants of planar-interdigitated conductivity sensors [14], for optimization of an electrolyte conductivity sensor [15], characterization of coplanar electrodes in microchannels [16,17], optimization for the detection of affinity binding of biomolecules [18], and to determine the electric field pattern of two-electrode structures in flow cytometer designs [19].…”
Section: Introductionmentioning
confidence: 99%