2011
DOI: 10.4103/0973-6042.91004
|View full text |Cite
|
Sign up to set email alerts
|

Combining of small fragment screws and large fragment plates for open reduction and internal fixation of periprosthetic humeral fractures

Abstract: Operative treatment of periprosthetic humeral fractures in elderly patients with osteoporotic bone requires a stable fixations technique. The combination of 3.5 cortical screws with washers in a 4.5 Arbeitsgemeinschaft für Osteosynthesefragen, Limited-contact dynamic compression plate or Locking plate, allows a stable periprosthetic fixation with the small 3.5 screws and 4.5 screws above and below the prosthesis, respectively. This combination is a cost-effective technique to treat periprosthetic humeral fract… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 11 publications
(15 reference statements)
0
7
0
2
Order By: Relevance
“…14,22,31 Forward flexion was > 100° or equal to the pre-fracture level in 11 of 13 patients in whom this was reported (from eight stud ies). 13,16,17,19,21,24,30,47 An arc of movement of the elbow of > 100° was reported in all four patients in whom it was reported from three studies. 18,27,29 A further seven patients (from two studies) had no pain at the fracture site.…”
Section: Revision Arthroplasty Complications Requiring Surgery 11 (14)mentioning
confidence: 83%
“…14,22,31 Forward flexion was > 100° or equal to the pre-fracture level in 11 of 13 patients in whom this was reported (from eight stud ies). 13,16,17,19,21,24,30,47 An arc of movement of the elbow of > 100° was reported in all four patients in whom it was reported from three studies. 18,27,29 A further seven patients (from two studies) had no pain at the fracture site.…”
Section: Revision Arthroplasty Complications Requiring Surgery 11 (14)mentioning
confidence: 83%
“…The prevalence of periprosthetic fracture after shoulder arthroplasty is 0.6% to 3% and it makes up 20% of complica-tions according to Steinmann, et al [1]. The incidence of peri-prosthetic fractures in the humerus is reported to be between 1.6% and 2.4% according to Seybold and al [2]. Periprosthetic fractures of the humerus following shoulder arthroplasty are very complex cases to treat and have a risk of complications and loss of function.…”
Section: Methodsmentioning
confidence: 99%
“…인공 견관절 전치환술 후 치환물 주위 골절의 발생률은 0.6%에서 2.4% 로 보고되고 있다. [1][2][3][4][5][6][7] 이는 인공 견관절 전치환술 후 발생하 는 합병증의 20% 정도를 차지한다. 4) 인공 견관절 전치환술 을 시행 받은 환자의 여명 증가 및 수술 후 활발한 활동으로 인공 치환물 주위 골절이 더욱 더 증가할 것으로 예상되고 있 다.…”
Section: 서 론unclassified
“…4) 인공 견관절 전치환술 을 시행 받은 환자의 여명 증가 및 수술 후 활발한 활동으로 인공 치환물 주위 골절이 더욱 더 증가할 것으로 예상되고 있 다. [1][2][3][4][5][6][7] 인공 치환물 주위 골절은 수술 중 또는 수술 후 합병증으 로 발생할 수 있다. 수술 중 골절은 기술적 결함으로 발생하 는 경우가 많고, 수술 후 골절은 외상 또는 치환물 주위 해리 와 관련이 있는 것으로 보고되었다.…”
Section: 서 론unclassified