2010
DOI: 10.1016/j.apenergy.2010.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Combining hydro and variable wind power generation by means of pumped-storage under economically viable terms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
56
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 155 publications
(59 citation statements)
references
References 27 publications
(44 reference statements)
1
56
0
Order By: Relevance
“…The PHS has been considered as a large storage system installed more than 95 GW all across the world, generally to promote the wind power integration to supply base load [83]. The need for exploiting PHS unit would be obvious through comparing the local networks demands to corresponding annual wind farm efficiency [81]. A novel strategy is proposed in [51] for self-scheduling (SS) of integrated wind farm and PHS unit.…”
Section: -Wind With Pumped Hydro Storagementioning
confidence: 99%
See 1 more Smart Citation
“…The PHS has been considered as a large storage system installed more than 95 GW all across the world, generally to promote the wind power integration to supply base load [83]. The need for exploiting PHS unit would be obvious through comparing the local networks demands to corresponding annual wind farm efficiency [81]. A novel strategy is proposed in [51] for self-scheduling (SS) of integrated wind farm and PHS unit.…”
Section: -Wind With Pumped Hydro Storagementioning
confidence: 99%
“…The possibility of integrating wind for an isolated electric grid is investigated wherein the operational parameters of PHS system are determined exploiting an integrated calculating algorithm to supply the electric energy on the basis of daily horizon. The most common and the best way to overcome the problems caused by wind power generation in isolated networks are utilizing hybrid hydro/wind schemes [62,[75][76][77][78][79][80][81][82]. That is the most appropriate way to optimally and desirably operate the available wind power capacity with high degree of penetration for small islands with low installed capacity is to use PHS units [62].…”
Section: -Wind With Pumped Hydro Storagementioning
confidence: 99%
“…The use of pumped hydro storage (PHS) for integration in the existing water supply system and increasing the wind penetration from 25% to 70% in the electricity supply of the Corvo island is proposed in [5] and a similar case, but which include sea desalination is given in [6]. The use of PHS for increasing wind penetration in the Lesbos island and algorithm for sizing the PHS units are described in [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…Case studies and calculations for pumped hydro and hydrogen have in many cases been proposed (Duić and Carvalho, 2004;Caralis and Zervos, 2006;Krajačić et al, 2008;Bueno and Carta, 2006;Kapsali and Kaldellis, 2010) or have been recently implemented, like in Madeira (Empresa de Electricidade da Madeira (EEM), 2010) or are under final construction, like on Ikaria Island in Greece (Public Power Corporation (PPC), 2010).…”
Section: Introductionmentioning
confidence: 99%