2019
DOI: 10.1002/14651858.cd013149.pub2
|View full text |Cite
|
Sign up to set email alerts
|

Combined proximal descending aortic endografting plus distal bare metal stenting (PETTICOAT technique) versus conventional proximal descending aortic stent graft repair for complicated type B aortic dissections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 62 publications
0
9
0
Order By: Relevance
“…We deployed a bare metal stent distally because it was favorable in the short-term. 27,28 This is the first report describing supraclavicular hybrid TEVAR for a patient with TBAD combined with three rare anomalies.…”
Section: Discussionmentioning
confidence: 90%
“…We deployed a bare metal stent distally because it was favorable in the short-term. 27,28 This is the first report describing supraclavicular hybrid TEVAR for a patient with TBAD combined with three rare anomalies.…”
Section: Discussionmentioning
confidence: 90%
“…8 The provisional extension to induce complete attachment (PETTICOAT) stent technique to treat acute type B aortic dissection has demonstrated efficacy in expanding the true lumen in the abdominal aorta. 12,13 Systematic reviews by Rong and colleagues 13 and Bertoglio and colleagues 14 both reported improved remodeling of the distal thoracoabdominal aorta at 12 months using the PETTICOAT technique, although studies were nonrandomized and primarily focused on patients with acute Debakey IIIb dissection with malperfusion. Few studies have focused on utilizing the PETTICOAT technique in chronic Debakey I/IIIb dissections to encourage distal thoracoabdominal aortic remodeling and reduce the need for thoracoabdominal aortic surgery or branched thoracoabdominal endovascular repair.…”
Section: Discussionmentioning
confidence: 99%
“… 20 Conversely, others have reported that bare-metal stenting may offer positive remodeling in the distal aorta. 21 , 22 , 23 , 24 , 25 Concerns have also been raised that the PETTICOAT technique may jeopardize future adjunctive endovascular procedures because of stent strut interference. Other investigators have countered that a more expanded true lumen facilitates adjunctive procedures by virtue of the increase in workspace.…”
Section: Discussionmentioning
confidence: 99%