2021
DOI: 10.1016/j.foodchem.2020.128156
|View full text |Cite
|
Sign up to set email alerts
|

Combined liquid phase microextraction and fiber-optics-based cuvetteless micro-spectrophotometry for sensitive determination of ammonia in water and food samples by the indophenol reaction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 44 publications
0
7
0
Order By: Relevance
“…The results are summarized in Table 2 , where an excellent recovery (96.0 ± 2.7–101.6 ± 3.1%) of the NH 4 + added was achieved, supporting the analytical utility of the established sensing probe method for the detection of NH 4 + in various water samples. The probe was further validated by measuring the concentration of NH 4 + in spiked tap and sea water samples by the established probe and the official micro-spectrophotometry [ 15 ] and the obtained results are summarized in Table 3 . A good agreement in terms of accuracy, precision and average recovery was achieved by the established probe and the official method [ 15 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The results are summarized in Table 2 , where an excellent recovery (96.0 ± 2.7–101.6 ± 3.1%) of the NH 4 + added was achieved, supporting the analytical utility of the established sensing probe method for the detection of NH 4 + in various water samples. The probe was further validated by measuring the concentration of NH 4 + in spiked tap and sea water samples by the established probe and the official micro-spectrophotometry [ 15 ] and the obtained results are summarized in Table 3 . A good agreement in terms of accuracy, precision and average recovery was achieved by the established probe and the official method [ 15 ].…”
Section: Resultsmentioning
confidence: 99%
“…NH 4 + is normally derivatized with o -phthalaldehyde (OPA) in HPLC to give an intensely fluorescent azaindole, whereas in GC mass spectrometry methods, an alkyl chloroformate such as butyl chloroformate is used to convert NH 4 + ions to higher molecular mass derivatives [ 10 , 11 , 12 ]. Other optical detection methods such as spectrophotometry [ 5 , 14 , 15 , 16 ], fluorescence-based emission [ 17 , 18 ] and colorimetry [ 19 ] have been reported for the detection of NH 4 + in environmental water samples. However, most of these techniques suffer from many drawbacks such as expensive equipment and elaborated sample pre-treatment; hence, it is of great importance to develop an efficient and cost-effective method for the detection of NH 3 /NH 4 + [ 17 , 18 ].…”
Section: Introductionmentioning
confidence: 99%
“…µQuEChERS was employed in the extraction of several analytes from foods, ranging from pesticide residues in wine [137] and PAHs in coffee and tea [138] to polyphenols in baby food [139] and pyrrolizidine alkaloids in oregano [66]. The application of SDME was proved to allow the determination of unfavorable compounds and elements in foods, such as drug metabolites [140], acrylamide [141], ammonia [142], ethyl carbamate [143], formaldehyde [144], tartrazine [145], and Cu(II) [146]. Similarly to SDME, SFOME can be used for the detection of trace metals [147], as well as of β-lactam antibiotic residues [148] and organochlorine pesticides [149].…”
Section: Food Samplesmentioning
confidence: 99%
“…Pipeline corrosion and other unfavourable effects might be avoided with the help of sulphide treatment, which was necessary for safety reasons [8]. At each stage of a well's lifecycle, SRB degradation poses a hazard that must be identified and counteracted [9]. According to the United States Geological Survey (USGS), one oil barrel requires 1,850 water gallons to retrieve and refine over the course of its lifetime.…”
Section: Introductionmentioning
confidence: 99%