Combined leadless pacemaker and subcutaneous implantable cardioverter-defibrillator to manage recurrent transvenous system failures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Indeed, a subsequent upgrade to a transvenous ICD is possible whenever indicated, although the risk of an upgrade procedure has to be considered. In few cases, subcutaneous ICD were combined successfully with CRT‐, His bundle‐, or leadless pacemaker 11‐13 . In patients with left ventricular dysfunction following myocardial infarction, implanted loop recorder data revealed high‐degree AV blocks in 10% and sinus arrest in 5% after 2 years 14 .…”
Section: Decision‐making For Implantation Of Ntv‐icdmentioning
confidence: 99%
“…Indeed, a subsequent upgrade to a transvenous ICD is possible whenever indicated, although the risk of an upgrade procedure has to be considered. In few cases, subcutaneous ICD were combined successfully with CRT‐, His bundle‐, or leadless pacemaker 11‐13 . In patients with left ventricular dysfunction following myocardial infarction, implanted loop recorder data revealed high‐degree AV blocks in 10% and sinus arrest in 5% after 2 years 14 .…”
Section: Decision‐making For Implantation Of Ntv‐icdmentioning
confidence: 99%
“…Though not specifically involving the CHD population, 2019 saw the release of several additional studies examining the real-world combination of leadless pacemakers and S-ICDs for both the application of bradycardia pacing as well as the termination of ventricular tachycardia with antitachycardia pacing. Ito et al, 5 Ljunstrom et al, 6 and Baroni et al 7 all described the successful implantation and midterm follow-up outcomes of patients who received an S-ICD and the Micra™ leadless pacemaker (Medtronic, Minneapolis, MN, USA). The patient described by Ito et al had prosthetic valve endocarditis precluding transvenous pacing but tolerated leadless pacing with no evidence of S-ICD crosstalk and displayed appropriate eligibility in all sensing vectors (ie, primary, secondary, and alternative) during ventricular pacing.…”
Section: Subcutaneous Implantable Cardioverter Defibrillatorsmentioning
confidence: 99%
“…The main disadvantage is the current impossibility to deliver Anti-Tachycardia-Pacing (ATP), and long-term conventional pacing. Nevertheless, these systems will be coupled with leadless pacemakers in the near future to overcome this specific, but important issue (32).…”
Section: Advances In Defibrillationmentioning
confidence: 99%