Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane

Abstract: The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-μs impulse) and the shape are consecutively measured within <200 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 49 publications
(69 reference statements)
0
12
0
Order By: Relevance
“…The MWHI method has been verified to reach an accuracy of 0.045 mm and exhibited repeatable measurements with 17 μm accuracy on a (National Institute of Standards and Technology) traceable ball and artificial samples [ 31 ]. This paper presents the results of TM shape measurements from three post-mortem human temporal bones (TB3, TB4, and TB5) under different manipulations.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The MWHI method has been verified to reach an accuracy of 0.045 mm and exhibited repeatable measurements with 17 μm accuracy on a (National Institute of Standards and Technology) traceable ball and artificial samples [ 31 ]. This paper presents the results of TM shape measurements from three post-mortem human temporal bones (TB3, TB4, and TB5) under different manipulations.…”
Section: Resultsmentioning
confidence: 99%
“…As described in [31], the MWHI method has been designed to sweep the synthetic wavelength allowing multiple measurements of shape in a short time. A tunable laser operating in open loop mode is used as a coherent light source, and continual wavelength tuning is achieved by changing the laser cavity length while keeping the number of waves in the cavity constant [38].…”
Section: Multiple Wavelength Holographic Interferometry (Mwhi) Methodmentioning
confidence: 99%