2020
DOI: 10.1016/j.rser.2019.109661
|View full text |Cite
|
Sign up to set email alerts
|

Combined heat and power from hydrothermal geothermal resources in Germany: An assessment of the potential

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 74 publications
(29 citation statements)
references
References 40 publications
2
23
0
Order By: Relevance
“…Table 4 summarises the yearly techno-economic performance of the integrated geothermal CHP system with mixed operation strategy. The global electric efficiency is equal to 13.4% and confirms that the parallel transcritical configuration guarantees high performance in line with medium and large-scale geothermal CHP systems [57]. The energy utilisation factor reaches 19.2% while the marginal efficiency of electric production is 14.4%.…”
Section: Hourly Energy Balance For the Selected Integrated Systemsupporting
confidence: 54%
See 2 more Smart Citations
“…Table 4 summarises the yearly techno-economic performance of the integrated geothermal CHP system with mixed operation strategy. The global electric efficiency is equal to 13.4% and confirms that the parallel transcritical configuration guarantees high performance in line with medium and large-scale geothermal CHP systems [57]. The energy utilisation factor reaches 19.2% while the marginal efficiency of electric production is 14.4%.…”
Section: Hourly Energy Balance For the Selected Integrated Systemsupporting
confidence: 54%
“…The electric energy injected to the grid is 62.6% and 49.2% of the daily production in July and October, respectively. that the parallel transcritical configuration guarantees high performance in line with medium and large-scale geothermal CHP systems [57]. The energy utilisation factor reaches 19.2% while the marginal efficiency of electric production is 14.4%.…”
Section: Hourly Energy Balance For the Selected Integrated Systemmentioning
confidence: 90%
See 1 more Smart Citation
“…In Figure 5, temperature-and flow rate-average structure of operational costs and average annualized capital costs for the reference case are compared with each other. Annualized capital costs were obtained with the help of an annuity factor [77], but such an approach was used only in this part of the work to allow for the comparison in Figure 5. It can be noted that electricity costs for pumping represent the biggest part of the OPEX.…”
Section: Economic and Ecological Resultsmentioning
confidence: 99%
“…Several publications investigate the energy conversion efficiency of the power cycle or the total power plant efficiencies 7,15,16 .…”
Section: State Of the Artmentioning
confidence: 99%