2020 IEEE KhPI Week on Advanced Technology (KhPIWeek) 2020
DOI: 10.1109/khpiweek51551.2020.9250131
|View full text |Cite
|
Sign up to set email alerts
|

Combined Defects Recognition in the Low and Medium Temperature Range by Results of Dissolved Gas Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 20 publications
0
2
0
1
Order By: Relevance
“…Some faults are very easy to diagnose using only a few of the diagnostic criteria. For example, C 2 H 6 as a key gas is typical for thermal faults in the temperature range of 150 to 300 • С and their combinations with electrical discharges [21,27]. The most common causes of such faults are weakening of the magnetic core pressing, local overheating of the core due to flux concentration, the presence of a short circuit, clogging of air dryer filters etc.…”
Section: Recognition Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…Some faults are very easy to diagnose using only a few of the diagnostic criteria. For example, C 2 H 6 as a key gas is typical for thermal faults in the temperature range of 150 to 300 • С and their combinations with electrical discharges [21,27]. The most common causes of such faults are weakening of the magnetic core pressing, local overheating of the core due to flux concentration, the presence of a short circuit, clogging of air dryer filters etc.…”
Section: Recognition Proceduresmentioning
confidence: 99%
“…It should also be noted that in some cases it is not sufficient to use only one diagnostic criterion to recognise the fault type. For example, for low‐temperature thermal fault that progresses to partial discharges [21], both the values of gas ratios and the percentage of gas content coincide with the values of the criteria characteristic of purely thermal faults. A similar situation occurs with some high‐temperature thermal fault that transform into discharges [22].…”
Section: Introductionmentioning
confidence: 98%
“…Для обладнання з відносно низьким вмістом масла (високовольтні вводи, трансформатори струму і напруги) схожість побудованих номограм з центрами областей №96, 98, 100 і 102 може свідчити про відкладення Х-воску [40]. Номограма, що збігається з центром області №97, наведена в [27] [46,55].…”
Section: аналіз графічних областей характерних для перегрівів у діапа...unclassified