Combined contrast-enhanced power Doppler and real-time sonoelastography performed during EUS, used in the differential diagnosis of focal pancreatic masses (with videos)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
91
0
4

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 112 publications
(95 citation statements)
references
References 45 publications
0
91
0
4
Order By: Relevance
“…Three recent meta-analyses found sensitivity of 95-99%, specificity of 69-76%, and accuracy of 89-96% [85][86][87]. The combination of power Doppler CEUS and elastography yielded global accuracy of 83%, with better specificity than elastography alone [88].…”
Section: Elastographymentioning
confidence: 99%
See 1 more Smart Citation
“…Three recent meta-analyses found sensitivity of 95-99%, specificity of 69-76%, and accuracy of 89-96% [85][86][87]. The combination of power Doppler CEUS and elastography yielded global accuracy of 83%, with better specificity than elastography alone [88].…”
Section: Elastographymentioning
confidence: 99%
“…Hypoenhancement on CEUS is considered suggestive of adenocarcinoma, due to the presence of a high proportion of desmoplastic tissue within the tumors, with few microvessels. Using a high mechanical index and Doppler CEUS, the hypovascular aspect was suggestive of adenocarcinoma in 83-94% of patients [88,[90][91][92][93][94]. Motion artifacts and blooming effect are frequent, however, and this method has been replaced by harmonic CEUS.…”
Section: Contrast-enhanced Eusmentioning
confidence: 99%
“…It has two subtypes with similar performance: contrast-enhanced endoscopic Doppler ultrasound (which uses a high mechanical index for examination and no special software) and contrast-enhanced low mechanical index endoscopic ultrasound (in which the examination is made in contrast mode) [51]. CE-EUS in Doppler mode is useful to differentiate between ductal adenocarcinomas (in which only arterioles are seen] and pseudotumoral chronic pancreatitis (in which both arterioles and venules can be identified by CE-EUS Doppler) [52,53].…”
Section: Contrast-enhanced Endoscopic Ultrasound (Ce-eus)mentioning
confidence: 99%
“…The high negative predictive value of the combination between elastography and contrast enhancement during EUS as reported [16] has raised hopes that these imaging methods might help the clinical decision making the process of differentiation between benign and malignant focal pancreatic masses, especially in patients with negative EUS-FNA samples.…”
Section: Introductionmentioning
confidence: 97%
“…Real-time elastographic EUS (RTE-EUS) and contrast-enhanced harmonic EUS (CEH-EUS) are two useful methods for the assessment of patients with focal pancreatic masses both reported to have a high sensitivity and specificity [11][12][13][14][15][16]. The high negative predictive value of the combination between elastography and contrast enhancement during EUS as reported [16] has raised hopes that these imaging methods might help the clinical decision making the process of differentiation between benign and malignant focal pancreatic masses, especially in patients with negative EUS-FNA samples.…”
Section: Introductionmentioning
confidence: 99%