2022
DOI: 10.31989/ffhd.v12i5.925
|View full text |Cite
|
Sign up to set email alerts
|

Combination of vitamins A, D2 and D3 reduce tumor load and alter the expression of miRNAs that regulate genes involved with apoptosis, tumor suppression, and the epithelial-mesenchymal transition in HCT-116 colon cancer cells

Abstract: Introduction: In previous work, we have shown the synergistic effects of combinations of vitamins A, D2, and D3 in reducing the proliferation of HCT-116 colon cancer cells. This combination also induced apoptosis and altered gene expression patterns as determined by transcriptomic profiling. Aims: The aims of this study were to investigate the effects of vitamins A and D in HCT-116 Crl:NU(NCr)-Foxn1nu mouse xenographs. Also, to determine potential mechanisms of action using miRNA-seq and correlated these data … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(11 citation statements)
references
References 56 publications
(92 reference statements)
0
11
0
Order By: Relevance
“…ATRA+D2+D3 combinations were added to the wells at the IC50 concentration for a final volume of 100 μl per well. The Caspase-Glo ® 3/7 and Caspase-Glo ® 8 assay kits (Promega Corporation, Madison, WI, USA) were used according to the manufacturer's protocols as we have described [33][34]. A Synergy HT Plate reader (Biotek, Winooski, VT, USA) and the Gen5 1.11 software analyzed and determined luminescence.…”
Section: Apoptosis Apotoxglo™ Triplex Assays Caspase-glo®3/7mentioning
confidence: 99%
See 4 more Smart Citations
“…ATRA+D2+D3 combinations were added to the wells at the IC50 concentration for a final volume of 100 μl per well. The Caspase-Glo ® 3/7 and Caspase-Glo ® 8 assay kits (Promega Corporation, Madison, WI, USA) were used according to the manufacturer's protocols as we have described [33][34]. A Synergy HT Plate reader (Biotek, Winooski, VT, USA) and the Gen5 1.11 software analyzed and determined luminescence.…”
Section: Apoptosis Apotoxglo™ Triplex Assays Caspase-glo®3/7mentioning
confidence: 99%
“…A Synergy HT Plate reader (Biotek, Winooski, VT, USA) and the Gen5 1.11 software analyzed and determined luminescence. The ApoToxGlo™ Triplex Assay kit was used according to the manufacturer's instructions and luminescence was measured using the Synergy HT Plate reader (Biotek, Winooski, VT) and Gen5 Table 1: Human primer sequences used for real-time PCR analysis are presented below and were obtained from previously published works [33][34][38][39][40].…”
Section: Apoptosis Apotoxglo™ Triplex Assays Caspase-glo®3/7mentioning
confidence: 99%
See 3 more Smart Citations