Combination of micro-dialysis and infrared spectroscopy: a multianalyte assay for accurate biofluid analysis and patient monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…Advantageously, this biosensor quantified other small molecules including glycerol. Since then, numerous biosensors coupled to microdialysis for the quantification of molecules found in body fluids, tissues, and organs other than the brain have been reported [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 ]. An earlier review of biochemical monitoring of various bodily fluids has been presented elsewhere [ 79 ].…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
See 2 more Smart Citations
“…Advantageously, this biosensor quantified other small molecules including glycerol. Since then, numerous biosensors coupled to microdialysis for the quantification of molecules found in body fluids, tissues, and organs other than the brain have been reported [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 ]. An earlier review of biochemical monitoring of various bodily fluids has been presented elsewhere [ 79 ].…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
“…Various applications of optical sensing have been performed both in a label-free or label-based manner. For label-based detection, the optical signal is acquired by fluorescent or colorimetric techniques [ 95 , 96 , 97 , 98 ], whereas label-free techniques involve light–analyte interactions to facilitate signal detection exemplified by spectroscopic biosensors [ 49 , 64 , 65 , 66 , 67 , 68 , 69 , 99 ]. Other than the widely used offline ISCUSflex colorimetric bedside analyser, all optical based techniques integrated with microdialysis to quantify TBI metabolites have utilised infrared spectroscopic sensors.…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
See 1 more Smart Citation
“…Dialysate infrared spectra were continuously measured in a 30-µm flow-through cell. Multivariate analyte quantification was applied using data within the spectral interval between 1600 and 980 cm -1 including consideration of the dialysis recovery rates to be independent from membrane fouling (see Figure 1); for further experimental details, see also Vahlsing et al 6 For standardization, two parameters are essential, ie, growth rate and number of cells after 60 hours with the onset of the exponential growth phase. By determining the normalized slope of the time-dependent glucose utilization until reaching the stationary glucose level within the cell culture (multiplication of the glucose concentration slope by the ratio of growth rate and number of cells after 60 hours), the potency of each tested insulin can be assessed when compared to certified insulin samples (see table in Figure 1).…”
mentioning
confidence: 99%
“…Dialysate infrared spectra were continuously measured in a 30-µm flow-through cell. Multivariate analyte quantification was applied using data within the spectral interval between 1600 and 980 cm –1 including consideration of the dialysis recovery rates to be independent from membrane fouling (see Figure 1); for further experimental details, see also Vahlsing et al 6…”
mentioning
confidence: 99%