2019
DOI: 10.1016/j.jfma.2018.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Combination of left atrial appendage closure and catheter ablation in a single procedure for patients with atrial fibrillation: Multicenter experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
16
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 23 publications
1
16
1
Order By: Relevance
“…The procedural-related complication/serious adverse event rate of combined therapy reported by two multicenter studies was 6.2% and 2.1% [ 9 , 12 ], which was consistent with the results of this study. A Chinese multicenter registry with the same population of our study documented a similar rate of 4.1% [ 11 ]. Our results support good periprocedural safety of the combined procedure.…”
Section: Discussionsupporting
confidence: 71%
“…The procedural-related complication/serious adverse event rate of combined therapy reported by two multicenter studies was 6.2% and 2.1% [ 9 , 12 ], which was consistent with the results of this study. A Chinese multicenter registry with the same population of our study documented a similar rate of 4.1% [ 11 ]. Our results support good periprocedural safety of the combined procedure.…”
Section: Discussionsupporting
confidence: 71%
“…In addition, catheter might potentially damage, dislodge and be entrapped by the device. Despite a previous study reporting similar outcomes as to performing ablation first or LAAC first, [ 28 ] we recommend performing ablation prior to LAAC.…”
Section: Discussionmentioning
confidence: 80%
“…Of these, 41 studies were further excluded because the index data were not available or effectively evaluated. The remaining 18 studies comprising two RCTs and 16 observational studies satisfied the inclusion criteria and were eventually included in this meta‐analysis. The literature search was conducted by two independent researchers (YJ and FL).…”
Section: Resultsmentioning
confidence: 99%
“…With regard to ablation strategy, one study used cryoballoon ablation, one study used RA and cryoballoon ablation, and the others used RA. As for the closure device, 11 studies used WATCHMAN (Boston Scientific, Natick, MA, USA), one study used LAmbre (Lifetech Scientific Corp., Shenzhen, China), and the other six studies used two closure devices: Amplatzer Cardiac Plug device (St. Jude Medical, Inc., St. Paul, MN, USA) and WATCHMAN. However, the outcomes were not reported separately based on each device.…”
Section: Resultsmentioning
confidence: 99%