2012
DOI: 10.1213/ane.0b013e31825d0a18
|View full text |Cite
|
Sign up to set email alerts
|

Combination of Laryngeal Mask Airway and Pediatric Boussignac Bougie for Difficult Tracheal Intubation in a Newborn with Goldenhar Syndrome

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 2 publications
0
2
0
1
Order By: Relevance
“…There is a paucity of literature on TTI use in infant intubations, which is limited to case reports, use for airway exchange, simulation models with anesthesiologists, and clinical descriptive use by pediatric anesthesiologist for few pediatric intubations. [17][18][19][20][21][22][23][24] In our infant simulation study, the FPS with the use of the TTI was low. Multiple airway operators commented that the device's lack of rigidity made it too difficult to direct.…”
Section: Discussionmentioning
confidence: 99%
“…There is a paucity of literature on TTI use in infant intubations, which is limited to case reports, use for airway exchange, simulation models with anesthesiologists, and clinical descriptive use by pediatric anesthesiologist for few pediatric intubations. [17][18][19][20][21][22][23][24] In our infant simulation study, the FPS with the use of the TTI was low. Multiple airway operators commented that the device's lack of rigidity made it too difficult to direct.…”
Section: Discussionmentioning
confidence: 99%
“…7 Bizim olgumuzda olduğu gibi ilk anestezi deneyiminde kateterin laringoskop eşliğinde trakeaya ilerletilememesi, ikinci uygulamada FOB ile indirekt görüntüleme altında düz bir şekilde başarısız olunması ve yine kateterin görerek ters bir şekilde yerleştirilebilmiş olması Camkıran ve ark.nın görüşünü desteklemektedir.…”
Section: Olgu Sunumuunclassified
“…There are both straight and distal angled types TTIs for use down to endotracheal tube size 2.5-3.0-3.5 (30). Vygon's Bougie Boussignac has been used successfully in the intubation of infants with Pierre Robin Syndrome (31,32) and TTIs and stylets combine well with videolaryngoscopy (33). Reports of complications with the use of bougies in neonates include pneumothoraxes and bronchial trauma (34) and controversy exist about under which circumstances, if any, a neonatal bougie should be used (34).…”
Section: Tracheal Tube Introducersmentioning
confidence: 99%