Combination of Forced Ventilation and Fogging Systems for Cooling Greenhouses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
36
0
1

Year Published

2005
2005
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(49 citation statements)
references
References 3 publications
2
36
0
1
Order By: Relevance
“…It is worth mentioning that no significant differences were found between the strategy of 12 s every 4min and 8 s every 4min; this result suggests that it is better to increase the cycle frequency than the fogging time in each cycle to increment flux. Studies varying the fogging rate have been conducted in the past (Arbel et al, 2003): the wet bulb temperature did not change significantly with an increase of the fogging rate, as this temperature mainly depends on the heat supply and the ventilation air supply.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is worth mentioning that no significant differences were found between the strategy of 12 s every 4min and 8 s every 4min; this result suggests that it is better to increase the cycle frequency than the fogging time in each cycle to increment flux. Studies varying the fogging rate have been conducted in the past (Arbel et al, 2003): the wet bulb temperature did not change significantly with an increase of the fogging rate, as this temperature mainly depends on the heat supply and the ventilation air supply.…”
Section: Resultsmentioning
confidence: 99%
“…Other studies analysed a range of variables in a combination of fogging and forced ventilation with fans on both sides of the greenhouse (e.g. Arbel et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…Sabeh humidity; and waste of water -to prevent blockage of wet pad water bleed is necessary," Arabel et al 3 . Sprinkling uses large surfaces (blankets) for faster evaporation installed overhead in greenhouses and wetted by mist nozzles.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The most desirable distribution of relative humidity was derived from the wind speed of 0.5 m·s -1 (Case 6). Arbel et al 4 reported that the entry velocity of the air into the greenhouse should not exceed about 0.5 m·s -1 in order to obtain uniform environmental conditions in the greenhouse.…”
Section: Simulation For a Multi-span Glasshousementioning
confidence: 99%