2016
DOI: 10.1016/j.cej.2016.07.108
|View full text |Cite
|
Sign up to set email alerts
|

Combination of anodic oxidation and biological treatment for the removal of phenanthrene and Tween 80 from soil washing solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
50
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 102 publications
(52 citation statements)
references
References 61 publications
0
50
0
Order By: Relevance
“…Few organic intermediates were detected at the very beginning of the electrolysis but total depletion was then observed . During the treatment of polycyclic aromatic hydrocarbons and TW80‐containing SW solution, a slight accumulation of short‐chain carboxylic acids was detected during the first hours of the treatment but the process was also able to achieve the mineralization of these compounds at longer treatment times . However, a different trend was reported by Saez et al.…”
Section: Application Of Bdd For Soil Remediationmentioning
confidence: 80%
See 3 more Smart Citations
“…Few organic intermediates were detected at the very beginning of the electrolysis but total depletion was then observed . During the treatment of polycyclic aromatic hydrocarbons and TW80‐containing SW solution, a slight accumulation of short‐chain carboxylic acids was detected during the first hours of the treatment but the process was also able to achieve the mineralization of these compounds at longer treatment times . However, a different trend was reported by Saez et al.…”
Section: Application Of Bdd For Soil Remediationmentioning
confidence: 80%
“…One of the major drawbacks of AO is still the energy consumption because of high charges required to reach full mineralization and detoxification of the solution. For example, 15 Ah L −1 , corresponding to 127 kWh m −3 , was required for achieving 70 % COD removal from a SW solution containing an initial organic load of 2,700 mg L −1 of COD . However the combination of AO with a more cost‐effective biological treatment can reduce global operating costs .…”
Section: Application Of Bdd For Soil Remediationmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, it was demonstrated that AOPs/EAOPs can enhance the biodegradability of recalcitrant effluents, measured by the ration BDO 5 /COD . More recently Oturan's group demonstrated that electro‐Fenton process can be utilized as pre‐treatment stage before a biological treatment ,. These studies have shown that the coupling between electro‐Fenton and biological degradation is a reliable strategy for removal of POPs from water in an efficient and cost‐effective way.…”
Section: Applications Of Bdd In Water and Wastewater Treatmentmentioning
confidence: 99%