2012
DOI: 10.1109/tmi.2012.2205586
|View full text |Cite
|
Sign up to set email alerts
|

Comb-Push Ultrasound Shear Elastography (CUSE): A Novel Method for Two-Dimensional Shear Elasticity Imaging of Soft Tissues

Abstract: Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2D shear elasticity map, multiple data acquisitions are typically required. In this paper, a novel shear elasticity imaging technique, comb-push ultrasound shear elastography (CUSE), is introduced in which only one rapid data acquisition (less than 35 ms) is need… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
174
1

Year Published

2016
2016
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 191 publications
(178 citation statements)
references
References 33 publications
1
174
1
Order By: Relevance
“…For shear wave motion estimation, 1-D normalized cross-correlation was performed, with kernel length of 2 mm (∼ 6λ) and step of 0.304 mm (∼ λ). To separate complex shear wave field into left and right travelling shear waves, directional filtering was performed [6]. For shear wave speed estimation, a 2-D shear wave speed estimation algorithm was applied with kernel size of 2.4 mm and patch size of 1.2 mm in the lateral and axial direction, as proposed by the [7].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…For shear wave motion estimation, 1-D normalized cross-correlation was performed, with kernel length of 2 mm (∼ 6λ) and step of 0.304 mm (∼ λ). To separate complex shear wave field into left and right travelling shear waves, directional filtering was performed [6]. For shear wave speed estimation, a 2-D shear wave speed estimation algorithm was applied with kernel size of 2.4 mm and patch size of 1.2 mm in the lateral and axial direction, as proposed by the [7].…”
Section: Methodsmentioning
confidence: 99%
“…For performance comparison, the background-to-inclusion ratio and contrast-to-noise ratio in dB were calculated for Young's modulus values, and a 5 x 5 mm rectangular region-of-interest (ROI) inside the inclusion, and two ROI surrounding the inclusion were used for these calculations. The following expression was used for CNR, where C I and C B are mean Young's modulus values in the inclusion and background, respectively; while σ B is standard deviation of the Young's modulus of the background [6] CNR = 20 log 10 |C…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…GE has implemented the "comb push" technique [11], which (as illustrated in ▶ Fig. 4) pushes along a number of ARFI lines simultaneously.…”
Section: Technology Of Ultrasound Elastographymentioning
confidence: 99%