Colorimetric detection of Cu2+ in aqueous solution and on the test kit by 4-aminoantipyrine derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 62 publications
(20 citation statements)
references
References 47 publications
1
18
0
1
Order By: Relevance
“…The Ninhydrin thiourea derivative 1 has been recrystallised from hot methanol which melts with decomposition at 195°C-205°C. Powder XRD and spectral studies (ESI-S2) of these compounds are consistent with the expected product [22] (SCHEME 1).…”
Section: Fig 1 Thiourea Derivative Of Ninhydrinsupporting
confidence: 68%
“…The Ninhydrin thiourea derivative 1 has been recrystallised from hot methanol which melts with decomposition at 195°C-205°C. Powder XRD and spectral studies (ESI-S2) of these compounds are consistent with the expected product [22] (SCHEME 1).…”
Section: Fig 1 Thiourea Derivative Of Ninhydrinsupporting
confidence: 68%
“…19,20 On the other hand, excessive Cu 2+ is harmful to the environment, 21 and colorimetric probes for Cu 2+ determination are widely used because they can monitor Cu 2+ both in solution and on test strips, which can be evaluated by the naked eye. 22,23 It has been noted that Schiff base sensors deserve special attention due to their simplicity, sensitivity, easy operation, and low cost. 15 Although a number of sensors towards two of Cu 2+ , Al 3+ , and Zn 2+ ions have been developed, 5,6,17,[23][24][25][26][27] simultaneous selective detection of all three ions by a molecular chemosensor based on a Schiff base scaffold is rarely reported.…”
Section: Introductionmentioning
confidence: 99%
“…It suggests that the significant role of these groups in binding with metal ions. Particularly, we have observed decreasing and broadening of imine and hydroxy peaks upon complexation with Hg 2+ , Cu 2+ , Cd 2+, and Pb 2+ ions . Further, we observed similar changes when compared to the free R2 with that of Hg 2+ and Cu 2+ complexes (Figure S16b) .…”
Section: Resultsmentioning
confidence: 99%
“…Among these, the colorimetric chemosensors are inexpensive, and it will detect the presence of an analyte in a small amount sample in which the target moiety is recognized by naked‐eye. On the other hand, colorimetric sensing methods offer numerous advantages in comparison with the other instrumental methods, viz terms of simple synthesis, sensitivity, field monitoring, fast results and they are non‐destructive …”
Section: Introductionmentioning
confidence: 99%