2018
DOI: 10.1016/j.ijbiomac.2018.02.093
|View full text |Cite
|
Sign up to set email alerts
|

Colorimetric detection of 1,5-anhydroglucitol based on graphene quantum dots and enzyme-catalyzed reaction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 40 publications
0
4
1
Order By: Relevance
“…In this regard, these concentrations are especially appropriate since the concentrations of this biomarker in blood, urine and saliva are notoriously lower than others (1.7–243 μmol L −1 ), as presented in Table 1. In addition, the LOD reported here (0.08 μmol L −1 ) is lower than that of other similar studies with LOD of 2.98, 54 and 0.88 μmol L −1 47‐49 …”
Section: Resultscontrasting
confidence: 80%
See 1 more Smart Citation
“…In this regard, these concentrations are especially appropriate since the concentrations of this biomarker in blood, urine and saliva are notoriously lower than others (1.7–243 μmol L −1 ), as presented in Table 1. In addition, the LOD reported here (0.08 μmol L −1 ) is lower than that of other similar studies with LOD of 2.98, 54 and 0.88 μmol L −1 47‐49 …”
Section: Resultscontrasting
confidence: 80%
“…In addition, the LOD reported here (0.08 μmol L −1 ) is lower than that of other similar studies with LOD of 2.98, 54 and 0.88 μmol L −1 . [47][48][49] All the buffer solutions used for this set of experiments were phosphate buffers (0.1 mol L −1 , pH 7) for galactose and 1,5-AHG HRP, horseradish peroxidase; LOD, limit of detection (3.3⊞/slope); LOQ, limit of quantification (10⊞/slope); TMB, 3,3 0 ,5,5 0 -tetramethylbenzidine.…”
Section: Quantitative Detection Of H 2 O 2 and Biomarkers In Buffermentioning
confidence: 99%
“…Z Zhou et al. ( 23 ) adopted a quantitative study for the colorimetric detection of serum 1,5-AG based on graphene quantum dots and enzyme-catalyzed reactions. Their findings indicated a linear correlation between the absorbance and the concentration of serum 1,5-AG in the range of 20.0–100.0 μg/mL, with a detection limit of approximately 0.144 μg/mL.…”
Section: Overview Of 15-agmentioning
confidence: 99%
“…Several methods have been explored to detect the level of serum 1,5-AG in a sensitive and accurate way. Routine techniques, such as the enzymatic method, chromatography, colourimetric assay, and mass spectrometry, have been used in clinical practice [ 4 , 9 , 10 , 11 , 12 , 13 ]. Currently, the Glycomark TM assay, approved by the United States Federal Drug Administration in 2003, is regarded as the gold standard to determine serum 1,5-AG levels [ 11 , 14 ].…”
Section: Introductionmentioning
confidence: 99%