2003
DOI: 10.1253/circj.67.49
|View full text |Cite
|
Sign up to set email alerts
|

Color Kinesis During Contrast-Enhanced Dobutamine Stress Echocardiography. Feasibility and Applicability.

Abstract: Accurate interpretation of dobutamine stress echocardiography (DSE) needs expertise. Color kinesis (CK) allows objective assessment of wall motion (WM), and its feasibility and accuracy are enhanced under harmonic imaging with contrast agents. To explore its utility, CK was performed in 41 unselected patients during contrast-enhanced DSE. After bolus injection of Levovist, the CK image was acquired in the apical 4- and 2-chamber views at baseline and peak stress using the ultraharmonic mode. Quad screen format… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 23 publications
(19 reference statements)
0
6
0
Order By: Relevance
“…CK has not been widely applied because of the requirement for proprietary software, labor intensive quantitation, and necessity for high-quality images. 91,92 The high sampling rates ($100 frames/sec) afforded by Doppler echocardiography enable assessment of both the timing and magnitude of contraction and relaxation. Both pulsed-wave (PW) and color Doppler techniques of tissue Doppler imaging (TDI) of myocardial segments have been investigated during dobutamine stress.…”
Section: Generally Limited To Assessment Of Longitudinal Function In mentioning
confidence: 99%
“…CK has not been widely applied because of the requirement for proprietary software, labor intensive quantitation, and necessity for high-quality images. 91,92 The high sampling rates ($100 frames/sec) afforded by Doppler echocardiography enable assessment of both the timing and magnitude of contraction and relaxation. Both pulsed-wave (PW) and color Doppler techniques of tissue Doppler imaging (TDI) of myocardial segments have been investigated during dobutamine stress.…”
Section: Generally Limited To Assessment Of Longitudinal Function In mentioning
confidence: 99%
“…[19][20][21][22] Briefly, parasternal long-and short-axis views of the left ventricle (LV) were digitally acquired at baseline. After obtaining the apical 4-chamber view, 2 ml of the intravenous contrast agent (Levovist, Schering AG, Germany; 300 mg/ml) was injected, and CE images were digitally acquired in the apical 4-and 2-chamber views.…”
Section: Ce-dsementioning
confidence: 99%
“…Software for automatic tracing of the endocardial border of the contrast-enhanced LV cavity is available offering the opportunity for achievement of highly reproducible measurements of FAC at rest and during stress [104] . Furthermore, methods have been developed for the quantitative assessment of regional myocardial perfusion, enabling simultaneous evaluation of regional LV function and perfusion [105,106] .…”
Section: Future Studiesmentioning
confidence: 99%