1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)
DOI: 10.1109/ultsym.1997.661864
|View full text |Cite
|
Sign up to set email alerts
|

Color Doppler spatial resolution measurements with an oscillating thin film test object

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Phillips et al developed an oscillating thin film test object, consisting of a number of precisely deposited sub-resolvable scatters for making spatial resolution and sensitivity measurements in colour Doppler [60,61]. The thin film consisted of a thin planar substrate that was acoustically matched to the surrounding media.…”
Section: Other Doppler Test Devicesmentioning
confidence: 99%
“…Phillips et al developed an oscillating thin film test object, consisting of a number of precisely deposited sub-resolvable scatters for making spatial resolution and sensitivity measurements in colour Doppler [60,61]. The thin film consisted of a thin planar substrate that was acoustically matched to the surrounding media.…”
Section: Other Doppler Test Devicesmentioning
confidence: 99%
“…oscillating thinfilm, or a modified string phantom consisting of two strings with adjustable separations. 5,6,8 The acoustic grid measured lateral spatial resolution for separations between 0.5 mm and 10 mm, 6 but the arrangement of the acoustic grids had potential to produce diffraction of the ultrasound beam. The modified string phantom provided measures of spatial resolution between 0.5 and 10 mm, 5 but measurements were carried out in water using Oring rubber, which has a significantly higher backscatter value than blood.…”
Section: Continuous and Pulsed Wave Spectral Doppler And Duplex Dopplmentioning
confidence: 99%
“…However, previous studies have evaluated colour Doppler spatial resolution based on an acoustic grid, an oscillating thin-film, or a modified string phantom consisting of two strings with adjustable separations. 5,6,8 The acoustic grid measured lateral spatial resolution for separations between 0 . 5 and 10 mm, 6 but the arrangement of the acoustic grids had potential to produce diffraction of the ultrasound beam.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation