Colombian Study to Assess the Use of Noninvasive Determination of the Endothelium-Mediated Vasodilation (CANDEV) II. Does Location of the Occlusion Device Affects the Accuracy of the Diagnosis?

Abstract: Endothelial dysfunction (ED), which is often evaluated by flow-mediated vasodilation (FMV) in the brachial artery, has been postulated as a predictor of cardiac events. Although the upper and forearm location of the occlusion device have been used for FMV evaluation, currently there is no consensus whether they provide the same information. The main goal of this study was to evaluate if both techniques have the same accuracy to differentiate subjects with and without cardiovascular risk factors (CRFs). A cross… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 33 publications
0
12
0
Order By: Relevance
“…The FMV was performed using a high-resolution Doppler ultrasound, measuring the changes in diameter of the brachial artery in response to increased blood flow (reactive hyperemia). This method was previously standardized in our population [21, 22]. …”
Section: Methodsmentioning
confidence: 99%
“…The FMV was performed using a high-resolution Doppler ultrasound, measuring the changes in diameter of the brachial artery in response to increased blood flow (reactive hyperemia). This method was previously standardized in our population [21, 22]. …”
Section: Methodsmentioning
confidence: 99%
“…Endothelium-dependent vasodilatation will be measured with the technique introduced by Silva et al [30], using the guidelines reported by Corretti et al [31] The diameter of the brachial artery will be assessed using a high-resolution ultrasound device (Siemens SG-60, USA), equipped with a 7.5 MHz linear array transducer and an integrated electrocardiography package. The ultrasound procedures will be performed with the subject resting quietly in supine position for at least 10 min.…”
Section: Methodsmentioning
confidence: 99%
“…The change in diameter caused by the increased flow will be calculated as the percentage change relative to the baseline measurement (FMD%). The dilating brachial artery response due to shear stress has been shown to have good accuracy and reproducibility [30,31]. Images will be recorded on DVD player, for subsequent measurements by two observers blinded to the study, finally, both measurements will be averaged.…”
Section: Methodsmentioning
confidence: 99%
“…The change in diameter caused by the increased flow will be calculated as the percentage change relative to the baseline measurement (FMD%). The dilator brachial artery response due to shear stress has been shown to have a good accuracy and reproducibility [24,36,37]. Images will be recorded on DVD player, and the measurements will be done by two observers blinded to the study and then both measurements will be averaged.…”