2008
DOI: 10.1016/j.jasms.2008.04.020
|View full text |Cite
|
Sign up to set email alerts
|

Collision induced dissociation-based characterization of nucleotide peptides: Fragmentation patterns of microcin C7–C51, an antimicrobial peptide produced by Escherichia coli

Abstract: Covalent© protein-nucleic© acid© conjugates© form© an© original© class© of© compounds© that© occur© in nature© or© can© be© generated© in© vitro© through© cross-linking© to© investigate© domains© involved© in protein/nucleic© acid© interactions.© Their© mass© spectrometry© fragmentation© patterns© are© poorly characterized.© We© have© used© electrospray-ionization© mass© spectrometry© (ESI-MS)© combined with© collision-induced© dissociation© (CID)© to© characterize© microcin© C7-C51,© an© antimicrobial nucleot… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Electrospray ionization (ESI) for analysis of crosslinks was employed at a later point, connecting liquid chromatography with triple quadrupole/linear ion trap (Q-trap [97,99]), quadrupole time-of-flight (Q-ToF [83][84][85][86]) or Orbitrap instruments [100]. Overall, on-line LC-ESI-MS requires much smaller sample quantities compared with off-line LC coupled with MALDI-MS and yields better sequence information.…”
Section: 4mentioning
confidence: 99%
See 1 more Smart Citation
“…Electrospray ionization (ESI) for analysis of crosslinks was employed at a later point, connecting liquid chromatography with triple quadrupole/linear ion trap (Q-trap [97,99]), quadrupole time-of-flight (Q-ToF [83][84][85][86]) or Orbitrap instruments [100]. Overall, on-line LC-ESI-MS requires much smaller sample quantities compared with off-line LC coupled with MALDI-MS and yields better sequence information.…”
Section: 4mentioning
confidence: 99%
“…Especially the low-mass cut-off is problematic, as this prevents the detection of marker ions (see below and Table 1), immonium ions and ions from very short peptide sequences. However, Petit et al demonstrated that MSMS in positive-and negative-ion mode can be applied to characterize an isolated microcin, comprising only seven amino acids and with its C-terminal amino acid covalently linked to a phosphoramidate group substituted with an adenosine and a propylamine [100]. Orbitrap instruments provide an additional mode of CID fragmentation, higher-energy C-trap dissociation (HCD).…”
Section: 4mentioning
confidence: 99%
“…A high‐performance liquid chromatography (HPLC) method coupled to tandem mass spectrometry (MS/MS) has been established as a critical and powerful analytical tool for protein analysis, nucleic acid analysis, molecular biology and structural characterization of macromolecules as well as in discovery of biomarkers for a variety of diseases 5–15. The present study reports the application of HPLC/nESI‐MS/MS (nESI: nano‐electrospray ionization) in revealing new structural characteristics of an acid PLA 2 isolated from Chinese Agkistrodon blomhoffii Ussurensis snake venom (ABUSV).…”
mentioning
confidence: 99%