Colistin susceptibility testing and Vitek-2™: is it really useless?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
10
0
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 3 publications
2
10
0
2
Order By: Relevance
“…However, the clonally related isolates were all from this hospital, and the isolates from other hospitals were unrelated. Some colistin-resistant isolates may have been missed, as only isolates shown to be resistant using Vitek were collected, and the limitations of the Vitek for colistin susceptibility testing have been described (Girardello et al, 2018). Likewise, colistinsusceptible isolates belonging to the same clone may have been missed, since the primary selection criterion was colistin resistance and the neonatal isolates were included fortuitously.…”
Section: Limitationsmentioning
confidence: 99%
“…However, the clonally related isolates were all from this hospital, and the isolates from other hospitals were unrelated. Some colistin-resistant isolates may have been missed, as only isolates shown to be resistant using Vitek were collected, and the limitations of the Vitek for colistin susceptibility testing have been described (Girardello et al, 2018). Likewise, colistinsusceptible isolates belonging to the same clone may have been missed, since the primary selection criterion was colistin resistance and the neonatal isolates were included fortuitously.…”
Section: Limitationsmentioning
confidence: 99%
“…Moreover, for K. pneumoniae and E. coli, the Vitek-2 provided better performance for isolates with MIC ≤ 0.5 and ≥ 16 µg/ mL than the isolates with MIC within > 0.5 and < 16 µg/mL. These results were presented by Girardello et al 26 that compared performance of Vitek-2 with BMD in determination of colistin susceptibility. The authors 26 reported a good correlation of results between Vitek-2 and BMD when tested K. pneumoniae and E. coli with isolates of MICs ≤ 0.5 and ≥ 16 µg/mL.…”
Section: Discussionmentioning
confidence: 62%
“…These results were presented by Girardello et al 26 that compared performance of Vitek-2 with BMD in determination of colistin susceptibility. The authors 26 reported a good correlation of results between Vitek-2 and BMD when tested K. pneumoniae and E. coli with isolates of MICs ≤ 0.5 and ≥ 16 µg/mL. In addition, the Vitek-2 was able to detect the resistance of 10 isolates of mcr-1-carrying E. coli although this polymyxin resistance mechanism exhibited borderline MICs of 4 µg/mL [6 isolates] and 8 µg/mL [4 isolates].…”
Section: Discussionmentioning
confidence: 74%
See 1 more Smart Citation
“…Bunun ana nedeni, büyük molekül ağırlığına sahip olan kolistinin agara difüzyonunun zor olması, bu durumun disk difüzyon ve gradiyent test yöntemlerinin performansını düşürmesidir 1 . Yapılan çalışmalarda, yarı-otomatize sistemlerin performanslarının da kolistin direncini saptamada yeterli olmadığı gösterilmiştir 4,5 . 2017 yılında "Clinical and Laboratory Standards Institute (CLSI)" ve "European Committee on Antimicrobial Susceptibility Testing (EUCAST)" ortak çalışma grubu, kolistin duyarlılığının belirlenmesinde polistren mikroplak ve kolistin sülfat tuzu kullanımını, referans yöntem olarak ise "International Organization for Standardization (ISO)" standart sıvı mikrodilüsyon yöntemine (SMD) (20776-1) göre çalışılmasını önermiştir 6,7 .…”
Section: Mi̇krobi̇yoloji̇ Bülteni̇unclassified