2014
DOI: 10.1016/j.tws.2014.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Cold-formed steel lipped and plain angle columns with fixed ends

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(15 citation statements)
references
References 11 publications
0
15
0
Order By: Relevance
“…10 It was found that the DSM local strength curve predicts reasonably well the numerical ultimate strengths of the shorter columns.…”
Section: Flexural-torsional Strength Curvesmentioning
confidence: 90%
See 2 more Smart Citations
“…10 It was found that the DSM local strength curve predicts reasonably well the numerical ultimate strengths of the shorter columns.…”
Section: Flexural-torsional Strength Curvesmentioning
confidence: 90%
“…The post-buckling behaviour, strength and design of angle columns has attracted the attention of several researchers in the past (e.g., [1][2][3][4][5][6][7][8][9][10][11]). Nevertheless, numerical simulations recently carried out by the authors [12,13], concerning pin-ended (but with end-section warping prevented) and fixed-ended short-to-intermediate equal-leg angle columns, shed new light on key (and somewhat surprising) mechanical aspects related with the structural response of such members, namely the fact that it is strongly influenced by the interaction between two global buckling modes (one involving major-axis flexure and torsion, and the other minor-axis flexure only) 1 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ungermann [33,34] dealt with experimental and numerical investigations on plain channels subjected to coupled instabilities. Post-buckling behavior of cold-formed steel columns was observed by Schafer [35].…”
Section: Introductionmentioning
confidence: 94%
“…Although the non-linear behaviour, strength and design of angle columns has attracted a lot of attention for decades (e.g., [1][2][3][4][5][6][7][8][9][10][11][12][13][14]), it was not until the last few years that the mechanics underlying the column non-linear behaviour were unveiled and properly understood [15,16] and it became clear why the current North American Specification (NAS) for Cold-Formed Steel Structures [17] still excludes short-to-intermediate equal-leg angle columns from (i) the pre-qualification for the Direct Strength Method (DSM) design and (ii) the application of the LFRD resistance factor / = 0.85, valid for all other cold-formed steel compression members. It was found that, although such columns buckle in flexural-torsional modes associated with a critical load plateau, the corresponding post-critical strength reserve changes considerably along that same plateau, thus affecting significantly the column failure load.…”
Section: Introductionmentioning
confidence: 99%