Coherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale

Abstract: We have designed a tool to measure the bunch length of an electron beam in a minimally invasive way by means of coherent Smith-Purcell radiation (SPR). The technique has been employed successfully at a test apparatus for the Mainz Energy-recovery Superconducting Accelerator MESA, demonstrating it is possible to determine the bunch length while losing less than 0.6% of the electron beam. The impact of the space charge on the bunch length can be reduced while tuning the longitudinal bunch preparation system duri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 9 publications
(9 reference statements)
0
3
0
Order By: Relevance
“…The most applications of the Smith-Purcell radiation use the coherent regime with the radiation intensity proportional to the square of the number of particles in the bunch (see, for example, [25,26]). Coherent effects in the radiation of electron bunches flying over static and dynamical periodic interfaces were studied in [22,27,28].…”
Section: Issca-2023mentioning
confidence: 99%
“…The most applications of the Smith-Purcell radiation use the coherent regime with the radiation intensity proportional to the square of the number of particles in the bunch (see, for example, [25,26]). Coherent effects in the radiation of electron bunches flying over static and dynamical periodic interfaces were studied in [22,27,28].…”
Section: Issca-2023mentioning
confidence: 99%
“…A reliable theoretical spectrum corresponding to the measurement conditions must be known when deriving the bunch form factor using coherent radiation. So far, some attempts have been made to measure bunch lengths from a few picoseconds to several hundred femtoseconds using coherent SPR [6,7]. The surface current (SC) model has been used as one of the methods to evaluate the theoretical spectrum of SPR.…”
Section: Introductionmentioning
confidence: 99%
“…Particles 2023, 5, FOR PEER REVIEW 2 several hundred femtoseconds using coherent SPR [6,7]. The surface current (SC) model has been used as one of the methods to evaluate the theoretical spectrum of SPR.…”
Section: Introductionmentioning
confidence: 99%