2017
DOI: 10.1016/j.matdes.2017.01.092
|View full text |Cite
|
Sign up to set email alerts
|

Coherent nanoscale X-ray probe for crystal interrogation at ID01, ESRF – The European Synchrotron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…[ 17 ] A schematic overview of the experimental set‐up is displayed in Figure 1 and described in more detail in ref. [ 18 ] The intensity distribution around the 002 or 111 Pt reflection was measured in vertical scattering geometry at an X‐ray energy of 9 keV.…”
Section: Resultsmentioning
confidence: 99%
“…[ 17 ] A schematic overview of the experimental set‐up is displayed in Figure 1 and described in more detail in ref. [ 18 ] The intensity distribution around the 002 or 111 Pt reflection was measured in vertical scattering geometry at an X‐ray energy of 9 keV.…”
Section: Resultsmentioning
confidence: 99%
“…two-dimensional MAXIPIX (ESRF, Grenoble, France) detector with a pixel size of 55 × 55 µm 2 , which was mounted 1260 mm downstream from the sample position. Further details of the experimental setup and the X-ray beam focusing at the ID01 beamline can be found in [26,27]. Prior to in situ three-point bending tests, the SFINX-tip and the nanofocused X-ray beam were aligned with respect to a pre-selected Au nanowire by optical microscopy, rendering a precision of a few micrometers followed by AFM imaging and scanning X-ray diffraction mapping using the K-mapping approach available at the ID01 beamline where the sample is continuously scanned through the beam and the diffraction yield at a selected Bragg peak is monitored [10].…”
Section: Resultsmentioning
confidence: 99%
“…The diffracted signal was recorded by a two-dimensional MAXIPIX (ESRF, Grenoble, France) detector with a pixel size of 55 × 55 µm 2 , which was mounted 1260 mm downstream from the sample position. Further details of the experimental setup and the X-ray beam focusing at the ID01 beamline can be found in [26,27].…”
Section: Methodsmentioning
confidence: 99%
“…The film was electron-beam evaporated on a lithographically patterned substrate consisting of $2 mm-sized holes in a marked 50 mm pitch grid. The focal profile of the beam was characterized using a 2D ptychography (Pfeiffer, 2018) approach on a test pattern featuring a 30 mm-diameter tungsten Siemens star placed close to the focal position of the KB mirrors (Leake et al, 2017). The patterned thin film eventually results in a regular array of crystals with a single and isolated particle in the centre of each square as illustrated by the scanning electron micrographs presented in Figs BCDI of Au particles was performed at the ID01 beamline at the European Synchrotron Radiation Facility (ESRF), Grenoble, France (Leake et al, 2019).…”
Section: Methodsmentioning
confidence: 99%