2010
DOI: 10.1088/1367-2630/12/3/035003
|View full text |Cite
|
Sign up to set email alerts
|

Coherent imaging of biological samples with femtosecond pulses at the free-electron laser FLASH

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
55
0
3

Year Published

2010
2010
2014
2014

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(58 citation statements)
references
References 40 publications
0
55
0
3
Order By: Relevance
“…For the discrete Fourier transform of a cyclic convolution of two sequences f N and g N one obtains in analogy to the continuous case 91) for F N and G N denoting the discrete Fourier transforms of f N and g N . Discrete correlation.…”
Section: The Discrete Fourier Transform 19mentioning
confidence: 99%
See 1 more Smart Citation
“…For the discrete Fourier transform of a cyclic convolution of two sequences f N and g N one obtains in analogy to the continuous case 91) for F N and G N denoting the discrete Fourier transforms of f N and g N . Discrete correlation.…”
Section: The Discrete Fourier Transform 19mentioning
confidence: 99%
“…beamline UE52-SGM of the Berlin electron storage ring Bessy II, a dedicated experimental vacuum chamber [91] was used that has been developed by the group of Dr. Axel Rosenhahn at the University of Heidelberg. The incident beam was focused by mirrors and/or confined by slits to a size of about 17.4(hrz.)…”
mentioning
confidence: 99%
“…Besides the tight gap between the two bacteria no inner structure can be resolved in the reconstructed hologram. However, a reconstruction is possible, which was not the case with previous CXDI data in the 3rd harmonic [20]. In the cited CXDI study, insufficient coherence was indicated as the most likely cause for the problems during the reconstruction.…”
Section: 4mentioning
confidence: 89%
“…Even though progress in solving the phase problem has been made in the last years [17][18][19], it remains challenging. At FLASH, recent CXDI data in the 3rd harmonic at a photon energy of 462 eV was recorded, but the phase retrieval was hampered due to the limited coherence length in this case [20,21]. Contrary to CXDI, holography [22] is a coherent projection microscopy technique.…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, microscopy with a resolution down to the scale of proteins 5,6 is feasible at large-scale facilities such as synchrotrons and more recently at x-ray free-electron lasers. [7][8][9] However, for the routine operation in a clinical environment drawing on these large-scale facilities is not an option.…”
Section: Introductionmentioning
confidence: 99%