2018
DOI: 10.1016/j.adro.2018.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Cochlea-sparing acoustic neuroma treatment with 4π radiation therapy

Abstract: PurposeThis study investigates whether 4π noncoplanar radiation therapy can spare the cochleae and consequently potentially improve hearing preservation in patients with acoustic neuroma who are treated with radiation therapy.Methods and materialsClinical radiation therapy plans for 30 patients with acoustic neuroma were included (14 stereotactic radiation surgery [SRS], 6 stereotactic radiation therapy [SRT], and 10 intensity modulated radiation therapy [IMRT]). The 4π plans were created for each patient with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2019
2019
2020
2020

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 39 publications
(56 reference statements)
0
9
0
1
Order By: Relevance
“…, left) modeled from mouse CT data was used to demonstrate a realistic application for the SOC, as described in Part I. Mouse liver and kidney structures were transferred from a contrast‐enhanced mouse CT, and the liver was targeted with a dose of 10 Gy using five beam angles optimized with the 4π algorithm . Film was inserted between the two phantom halves for dose measurement.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…, left) modeled from mouse CT data was used to demonstrate a realistic application for the SOC, as described in Part I. Mouse liver and kidney structures were transferred from a contrast‐enhanced mouse CT, and the liver was targeted with a dose of 10 Gy using five beam angles optimized with the 4π algorithm . Film was inserted between the two phantom halves for dose measurement.…”
Section: Methodsmentioning
confidence: 99%
“…Mouse liver and kidney structures were transferred from a contrast-enhanced mouse CT, and the liver was targeted with a dose of 10 Gy using five beam angles optimized with the 4p algorithm. [48][49][50][51][52][53][54][55][56][57][58] Film was inserted between the two phantom halves for dose measurement.…”
Section: F Dosimetric Testingmentioning
confidence: 99%
“…CG has been shown to be effective for BOO in radiation therapy problems. 15,21,61 While CG does not guarantee an optimal solution, the CG algorithm has been shown to have superior performance when compared to clinical plans, 10,15,21,30,50,52,53,[62][63][64][65][66][67][68][69][70] and the algorithm is summarized in the sections that follow. A list of all indices, parameters, variables, and functions used in this paper and their definitions are provided in Table I.…”
Section: C Full and Limited Boo Problemmentioning
confidence: 99%
“…The voxel resolution was 0.5 mm 3 for the Mouse U and UC plans and 0.1 mm 3 for the Mouse Liver and Audrey plans. The 4p beam orientation optimization method, which differs from the RAO method described and has been previously published extensively, [34][35][36][37][38][39][40][41][42][43][44] was then used to find optimal beam angles for each plan. This optimization is based on a greedy column generation approach which iteratively selects beams from a candidate pool.…”
Section: B Rao Evaluationmentioning
confidence: 99%