Coaxial Probe-based Measurements of Biological Tissues: Inaccuracies in Sensing Volume when Calculated from Sensing Radius and Sensing Depth

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…The minimum homogeneous sample size can be determined by: i) positioning a flat high-contrast material layer behind a sample that has dielectric properties close to those which are the target of the experimental campaign, and increasing the sample thickness until the high-contrast material is not detectable in the reflection measurements (i.e., the measurements reach steady values even with increasing thickness), and ii) positioning a cylindrical high-contrast material layer around a cylindrical inner sample that has dielectric properties close to those which are the target of the experimental campaign, and increasing the sample radius until the highcontrast material is not detectable in the reflection measurements [85]. (Note that a low-contrast material could also be used in these steps, particularly if it is of a similar contrast to tissue heterogeneities that would be expected to exist in the region surrounding the homogeneous tissue region that is the measurement target).…”
Section: Sample Size Requirementsmentioning
confidence: 99%
See 1 more Smart Citation
“…The minimum homogeneous sample size can be determined by: i) positioning a flat high-contrast material layer behind a sample that has dielectric properties close to those which are the target of the experimental campaign, and increasing the sample thickness until the high-contrast material is not detectable in the reflection measurements (i.e., the measurements reach steady values even with increasing thickness), and ii) positioning a cylindrical high-contrast material layer around a cylindrical inner sample that has dielectric properties close to those which are the target of the experimental campaign, and increasing the sample radius until the highcontrast material is not detectable in the reflection measurements [85]. (Note that a low-contrast material could also be used in these steps, particularly if it is of a similar contrast to tissue heterogeneities that would be expected to exist in the region surrounding the homogeneous tissue region that is the measurement target).…”
Section: Sample Size Requirementsmentioning
confidence: 99%
“…It should be chosen with the target uncertainty in mind. It should also be noted that the sensing volume is best determined by restricting the sensing radius and the sensing depth simultaneously, as thresholds for change in one dimension are not consistent with simultaneous volume changes in both dimensions [85].…”
Section: Sample Size Requirementsmentioning
confidence: 99%