2005
DOI: 10.1161/circulationaha.104.478222
|View full text |Cite
|
Sign up to set email alerts
|

Coagulation Assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
207
0
2

Year Published

2010
2010
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 186 publications
(213 citation statements)
references
References 56 publications
1
207
0
2
Order By: Relevance
“…However, its application is limited to a small number of specialized laboratories [11,12]. Several methods have been published to assess dabigatran activities, which mainly involved normal plasma samples spiked in vitro with increasing amounts of the NOAC [3,[13][14][15][16][17] or under real-life conditions [10-12, 18, 19]. The investigation aims to add to the literature the measurement of dabigatran in other biological samples than plasma such as serum and urine and to give additional data of blood samples in reallife situations, which are needed to improve medical care of acutely diseased patients.…”
Section: Introductionmentioning
confidence: 99%
“…However, its application is limited to a small number of specialized laboratories [11,12]. Several methods have been published to assess dabigatran activities, which mainly involved normal plasma samples spiked in vitro with increasing amounts of the NOAC [3,[13][14][15][16][17] or under real-life conditions [10-12, 18, 19]. The investigation aims to add to the literature the measurement of dabigatran in other biological samples than plasma such as serum and urine and to give additional data of blood samples in reallife situations, which are needed to improve medical care of acutely diseased patients.…”
Section: Introductionmentioning
confidence: 99%
“…Although the LMWHs all bind to AT, they demonstrate different abilities to enhance inactivation of FXa and/or thrombin (anti-FXa:anti-FIIa ratios ranging from 2:1 to 4:1) [8].…”
Section: Introductionmentioning
confidence: 99%
“…First, since the APTT is a standard end-point clotting time assay, it can be influenced by many other coagulation variables. For example, the APTT will be prolonged by inherited or acquired coagulation factor deficiencies (including factors XII, XI, X, IX, VIII, V, and II) [8,12]. Second, more than 300 different laboratory tests are in clinical use to measure the APTT.…”
Section: Introductionmentioning
confidence: 99%
“…PT, aPTT and fibrinogen were measured with a semi-automated technique using fibrin timer (Siemens, Behring, Marburg, Germany) [10,11].…”
Section: Methodsmentioning
confidence: 99%