2018
DOI: 10.1016/j.cej.2018.08.107
|View full text |Cite
|
Sign up to set email alerts
|

Co-treatment of septage and municipal wastewater in a quadripartite microbial desalination cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…It happened mainly because of ohmic resistance and subsequently, power generation was substantially affected by ionic characteristics of solutions. The ohmic resistance has been considered as one of the key factors to achieve the maximum power density in fuel cells 28 . Thus, increasing the conductivity of the electrolyte solution decreased the ohmic resistance of MEKC 6.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It happened mainly because of ohmic resistance and subsequently, power generation was substantially affected by ionic characteristics of solutions. The ohmic resistance has been considered as one of the key factors to achieve the maximum power density in fuel cells 28 . Thus, increasing the conductivity of the electrolyte solution decreased the ohmic resistance of MEKC 6.…”
Section: Resultsmentioning
confidence: 99%
“…Solar energy, as well as microbial fuel cells (MFCs), have been considered as effective methods to be combined with EKR 22,24‐27 . Among these approaches, MFC as a nascent applied science in wastewater treatment, clean water production, 28‐30 and green energy generation, 30,31 have been proposed in recent years. The previous studies findings have shown the high potential of MFC in producing renewable and low‐cost energy sources 32‐34 .…”
Section: Introductionmentioning
confidence: 99%
“…Open circuit voltage (OCV), current and voltage were measured according to the methodology described elsewhere 68 , 69 . Derived electrochemical parameters such as current density, power density, and volumetric power density were calculated based on the cathode surface area.…”
Section: Methodsmentioning
confidence: 99%
“…A few creators consider the volume of regarded water as a variable when measuring proficiency for water organizations that give drinking water also wastewater treatment administrations. This estimate is not valuable as an estimation of specialized and monetary working proficiency of WWTPs since it doesn't represent toxin disposal yields or cost elements particular to the wastewater treatment handle [25]. An alternate approach, particularly for specialized and financial efficiencies of WWTPs, has been utilized by Hernández-Sancho and Sala-Garrido [12].…”
Section: Energy Efficiency Of Wastewater Treatmentmentioning
confidence: 99%