“…Therefore, this brief review covers only recent studies that use CFD tools for analysing indoor airflow and thermal performance of ventilated or unconditioned spaces, some of which are used as references for choosing appropriate simulation parameters. Transient simulation of hygrothermal performance of buildings was carried out by Mirsadeghi [54]. The author had used experimental results available in previous literature to validate the simulations employing standard k-ω model along with low-Re correction and Boussinesq approximation.…”
Section: Transient Simulation Of Unconditioned/ventilated Spacesmentioning
confidence: 99%
“…For this purpose, two references from literature dealing with different conditions of indoor air simulation are used here. The first is the work by Mirsadeghi [54] in which the author compared the results of transient thermal analysis of an enclosed space using three different methods: material properties, mesh, and simulation parameters were the same as those used in the reference.…”
Section: Reference Cases For Validationmentioning
confidence: 99%
“…Figure3: The models used in the references selected for validation: (a) transient simulation of an enclosed space[54] and (b) steady-state simulation and experiment comparative study of a ventilated space[58].…”
mentioning
confidence: 99%
“…Figure5: Comparison of the results between the reference and current simulation: (a) average indoor air temperature[54] (b) average inside surface temperature of the north wall[54], and (c) inside surface temperature variation near the hot wall[58].…”
“…Therefore, this brief review covers only recent studies that use CFD tools for analysing indoor airflow and thermal performance of ventilated or unconditioned spaces, some of which are used as references for choosing appropriate simulation parameters. Transient simulation of hygrothermal performance of buildings was carried out by Mirsadeghi [54]. The author had used experimental results available in previous literature to validate the simulations employing standard k-ω model along with low-Re correction and Boussinesq approximation.…”
Section: Transient Simulation Of Unconditioned/ventilated Spacesmentioning
confidence: 99%
“…For this purpose, two references from literature dealing with different conditions of indoor air simulation are used here. The first is the work by Mirsadeghi [54] in which the author compared the results of transient thermal analysis of an enclosed space using three different methods: material properties, mesh, and simulation parameters were the same as those used in the reference.…”
Section: Reference Cases For Validationmentioning
confidence: 99%
“…Figure3: The models used in the references selected for validation: (a) transient simulation of an enclosed space[54] and (b) steady-state simulation and experiment comparative study of a ventilated space[58].…”
mentioning
confidence: 99%
“…Figure5: Comparison of the results between the reference and current simulation: (a) average indoor air temperature[54] (b) average inside surface temperature of the north wall[54], and (c) inside surface temperature variation near the hot wall[58].…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.