cMiCE:a high resolution animal PET using continuous LSO with a statistics based positioning scheme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 24 publications
0
13
0
Order By: Relevance
“…They are also characterized by the highest light output (i.e., number of photons emitted per unit of deposited energy), which is directly related to the energy resolution. Most PET and SPECT systems are composed of pixelated scintillators to assign the interaction position of the gamma photon [74], although blocks made of continuous crystal have been proposed as well [75,76]. Table 3 lists some of the scintillators commonly used in CT, SPECT and PET detector systems together with their key properties [77][78][79][80][81].…”
Section: Detector Technology For Ct Spect and Petmentioning
confidence: 99%
“…They are also characterized by the highest light output (i.e., number of photons emitted per unit of deposited energy), which is directly related to the energy resolution. Most PET and SPECT systems are composed of pixelated scintillators to assign the interaction position of the gamma photon [74], although blocks made of continuous crystal have been proposed as well [75,76]. Table 3 lists some of the scintillators commonly used in CT, SPECT and PET detector systems together with their key properties [77][78][79][80][81].…”
Section: Detector Technology For Ct Spect and Petmentioning
confidence: 99%
“…8). More intelligent positioning algorithms [14] are under investigation to expand the dynamic range of the sheet crystal positioning and improve linearity near the FOV edge. Note the measured dynamic range also improves by 28% if we remove the crystal edge reflector, but this reduces the measured light collection by 27% and energy resolution by 16%.…”
Section: Summary and Discussionmentioning
confidence: 99%
“…The devices were fabricated using a planar process similar to that used for APD array fabrication [13]. The prototype PSAPD devices have a sensitive area of 8 8 and 14 14 . Packaged on a ceramic substrate they are thick.…”
Section: B Position Sensitive Avalanche Photodiode (Psapd) Configuramentioning
confidence: 99%