2013
DOI: 10.1007/s13361-013-0720-z
|View full text |Cite
|
Sign up to set email alerts
|

Clustering and Filtering Tandem Mass Spectra Acquired in Data-Independent Mode

Abstract: Data-independent mass spectrometry activates all ion species isolated within a given mass-to-charge window (m/z) regardless of their abundance. This acquisition strategy overcomes the traditional data-dependent ion selection boosting data reproducibility and sensitivity. However, several tandem mass (MS/MS) spectra of the same precursor ion are acquired during chromatographic elution resulting in large data redundancy. Also, the significant number of chimeric spectra and the absence of accurate precursor ion m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…Additionally, DIA MS1 information (precursor peptide measurement scans) has not been systematically incorporated into DIA scoring so far, and the lack of accurate precursor mass leads to ambiguity in data interpretation, especially for peptides co-isolated in the same DIA window and sharing fragment ion peaks. Only a few computational tools 4, 18, 19 have been developed so far for untargeted peptide identification from DIA and they have not been tested on SWATH-like DIA methods nor are they capable of performing both identification and quantification.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, DIA MS1 information (precursor peptide measurement scans) has not been systematically incorporated into DIA scoring so far, and the lack of accurate precursor mass leads to ambiguity in data interpretation, especially for peptides co-isolated in the same DIA window and sharing fragment ion peaks. Only a few computational tools 4, 18, 19 have been developed so far for untargeted peptide identification from DIA and they have not been tested on SWATH-like DIA methods nor are they capable of performing both identification and quantification.…”
Section: Introductionmentioning
confidence: 99%
“…We centrally acquired high quality benchmarking data sets using different instrument platforms and acquisition modes, and focused our comparative analysis on five widely-used analysis tools for SWATH-MS data: four ‘peptide-centric’ query17 tools (OpenSWATH18, SWATH2.0, Skyline19, and Spectronaut20) and the ‘data-centric’ approach DIA-Umpire19. While the former use MS/MS libraries to extract groups of signals that reliably represent a specific peptide, followed by statistical methods to distinguish true from false matches14,18,21, the latter assembles “pseudo” tandem MS spectra that can be identified and quantified with conventional database-searching and protein-inference tools without an assay library8,22. All respective software developers participated in our study, ensuring an optimal analysis workflow and parameters for each SWATH software tool.…”
Section: Introductionmentioning
confidence: 99%
“…Analytical Methods PaperPublished on13 March 2014. Downloaded by University of Windsor on 26/06/2014 16:39:15.…”
mentioning
confidence: 99%