2014
DOI: 10.1016/j.jchromb.2014.01.055
|View full text |Cite
|
Sign up to set email alerts
|

Cloud point extraction–HPLC method for the determination and pharmacokinetic study of aristolochic acids in rat plasma after oral administration of Aristolochiae Fructus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…When rats orally administrated with 8 mg/kg AAI, the C max of AAI was 1352.8 ng/mL (Liu et al, 2010). When rats orally administrated with 30 g/kg Aristolochiae Fructus extract, the C max of AAI was about 2056.6 ng/mL (Ren et al, 2014). Intestinal tract is the main site of food digestion and absorption, and also the main site of drug absorption.…”
Section: Introductionmentioning
confidence: 99%
“…When rats orally administrated with 8 mg/kg AAI, the C max of AAI was 1352.8 ng/mL (Liu et al, 2010). When rats orally administrated with 30 g/kg Aristolochiae Fructus extract, the C max of AAI was about 2056.6 ng/mL (Ren et al, 2014). Intestinal tract is the main site of food digestion and absorption, and also the main site of drug absorption.…”
Section: Introductionmentioning
confidence: 99%
“…Five AAs, shown in Fig. 1 , were separated and purified in our laboratory and their purities were no lower than 98% [ 13 , 26 ]. Methanol and acetonitrile were HPLC grade (Fairfield, OH, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Nowadays, the pharmacokinetic studies about AAs focus mainly on AA I [ 17 19 ] and/or AA II [ 20 25 ]; the other AAs are seldom involved. Very recently, the preliminary pharmacokinetics of 4 AAs in AF have been investigated by the CPE -HPLC (cloud point extraction-high performance liquid chromatography) method [ 26 ]. However, the method is tedious and produces data with relatively poor sensitivity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The type of surfactant used is also very important. Triton X-114 is more frequently chosen for the analysis of biological fluids than other surfactants such as Triton X-100 and Genapol X-080 [14][15][16][17][18][19][20][21][22][23]. This is due to its low cloud-point temperature (23°C) and high density which facilitate phase separation by centrifugation [14].…”
Section: Optimization Of the Cpe Proceduresmentioning
confidence: 99%