2014
DOI: 10.1017/s1047951114000183
|View full text |Cite
|
Sign up to set email alerts
|

Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder

Abstract: The Amplatzer Septal Occluder is a good alternative to percutaneously treat large and hypertensive ductus arteriosus.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
13
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 8 publications
(21 reference statements)
2
13
1
Order By: Relevance
“…Only one patient experienced moderate pulmonary hypertension immediately after procedure; that patient recovered after 6 months of regular treatment with bosentan. Furthermore, the LA diameter and LVEDD of all infants decreased by the 6-month follow-up and eventually returned to normal, which was consistent with the results of a previous study [5]. The ductus arteriosus is the connection between the main PA and the distal part of aortic arch; it serves as the main pathway of fetal blood circulation.…”
Section: Discussionsupporting
confidence: 90%
“…Only one patient experienced moderate pulmonary hypertension immediately after procedure; that patient recovered after 6 months of regular treatment with bosentan. Furthermore, the LA diameter and LVEDD of all infants decreased by the 6-month follow-up and eventually returned to normal, which was consistent with the results of a previous study [5]. The ductus arteriosus is the connection between the main PA and the distal part of aortic arch; it serves as the main pathway of fetal blood circulation.…”
Section: Discussionsupporting
confidence: 90%
“…In 11 cases the initially implanted Amplatzer ductal occluder (ADO) or Amplatzer muscular ventricular septal occluder (AMVSDO) either embolised, were instable and slipped through the duct or protruded significantly into the left pulmonary artery (LPA). Devices were retrieved and changed to the Amplatzer Septal Occluder with which successful occlusion was accomplished . Thanopoulos et al describe their experience with the AMVSDO in seven patients with PAH and equivalent PDA diameters (7–13 mm) compared to our cohort.…”
Section: Discussionmentioning
confidence: 53%
“…Transcatheter closure of a patent ductus arteriosus (PDA) is performed since almost 50 years, starting with Porstmann's ivalon plug in 1967 . The interventionalist's armamentarium nowadays consists of a wide range of various occluder types and coils, mostly nitinol‐based and self‐expanding . The closing procedure itself is considered a standard procedure in most pediatric cath labs with excellent results .…”
Section: Introductionmentioning
confidence: 99%
“…For lager PDAs, the Amplatzer mVSD occluder is an effective choice yet, particularly for those complicated with severe pulmonary arterial hypertension. [7][8][9][10][11] The mVSD occluder manufactured in China is similar to the Amplatzer occluder. We choose the mVSD occluder because the duct in our case was large and the pulmonary pressure was high.…”
Section: Discussionmentioning
confidence: 99%