2018
DOI: 10.3390/electronics7070117
|View full text |Cite
|
Sign up to set email alerts
|

Closing the Wearable Gap: Mobile Systems for Kinematic Signal Monitoring of the Foot and Ankle

Abstract: Interviews from strength and conditioning coaches across all levels of athletic competition identified their two biggest concerns with the current state of wearable technology: (a) the lack of solutions that accurately capture data “from the ground up” and (b) the lack of trust due to inconsistent measurements. The purpose of this research is to investigate the use of liquid metal sensors, specifically Liquid Wire sensors, as a potential solution for accurately capturing ankle complex movements such as plantar… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
51
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 23 publications
(53 citation statements)
references
References 36 publications
2
51
0
Order By: Relevance
“…Regardless of the challenges, this research team remains confident that an accurate gait assessment that rivals the accuracy of 3D motion capture systems can still be achieved using only four off-the-shelf SRS sensors. As is consistent with the Conclusions Section in Part II of the "closing the wearable gap" paper series: "the solution verified on human participants within this study essentially creates a real-time, continuous, and consistent electric goniometer that a user can wear to assess their movements accurately" [8].…”
Section: Discussionsupporting
confidence: 81%
See 4 more Smart Citations
“…Regardless of the challenges, this research team remains confident that an accurate gait assessment that rivals the accuracy of 3D motion capture systems can still be achieved using only four off-the-shelf SRS sensors. As is consistent with the Conclusions Section in Part II of the "closing the wearable gap" paper series: "the solution verified on human participants within this study essentially creates a real-time, continuous, and consistent electric goniometer that a user can wear to assess their movements accurately" [8].…”
Section: Discussionsupporting
confidence: 81%
“…Therefore, utilizing the mean MAE for fit considers that not all errors may be preventable and should not overly penalize the fit score. However, given that the goal of this entire project and "closing the wearable gap" paper series is to design a device that meets the needs of the practitioners by accurately capturing foot-ankle data "from the ground up" [8], then perhaps the more penalized score provided by mean RMSE is a more realistic appropriation of fit. Variance by five degrees in the calculation of a joint angle may not be viewed by a practitioner as problematic for flexion-based movements given that the foot-ankle joint can move in much wider arcs in the sagittal plane.…”
Section: Mean Rmsementioning
confidence: 99%
See 3 more Smart Citations