2017
DOI: 10.1089/dia.2017.2504
|View full text |Cite
|
Sign up to set email alerts
|

Closing the Loop

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 77 publications
0
6
0
Order By: Relevance
“…In these days from control point of view the most beneficial approach is the Artificial Pancreas (AP) concept. This idea aims to imitate the regular operation of the pancreas from the insulin production point of view, namely, administering insulin demands on the needs determined by the BG level [19]. Thus, we have to face contradictory requirements: the generalization and personalization as well.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In these days from control point of view the most beneficial approach is the Artificial Pancreas (AP) concept. This idea aims to imitate the regular operation of the pancreas from the insulin production point of view, namely, administering insulin demands on the needs determined by the BG level [19]. Thus, we have to face contradictory requirements: the generalization and personalization as well.…”
Section: Introductionmentioning
confidence: 99%
“…The most frequently used method is the Model Predictive Control (MPC) regarding the control of DM [19,[26][27][28]. MPC is a widely used approach in various research fields as well [29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…Sampling time T was chosen to be T = 5 min due to the current blood glucose concentration measuring devices are capable of providing data at similar frequencies [5], [13] with one exception. During our investigations it became clear that the Adams-Bashforth method was not able to provide acceptable outcome with T = 5.…”
Section: Resultsmentioning
confidence: 99%
“…For example, the sampling frequency is around 5 minutes on basis, noise and disturbance sensitivity, inaccuracies of available mathematical models, etc. [2], [5], [14]. State estimation for control applications is also an important aspect which is not trivial and the requirements of it determined by the type of control to be applied [15], [16].…”
Section: Introductionmentioning
confidence: 99%
“…Current continuous glucose monitoring systems (CGMS) achieve 5-minutes-long sampling periods [3]. The sparseness of the measurements is only one obstacle in the control design procedure, others include noises and disturbances or the uncertainty of the mathematical model [4]- [6].…”
Section: Introductionmentioning
confidence: 99%