2019 IEEE 10th Control and System Graduate Research Colloquium (ICSGRC) 2019
DOI: 10.1109/icsgrc.2019.8837093
|View full text |Cite
|
Sign up to set email alerts
|

Closed Loop Control of SEPIC DC-DC Converter Using Loop Shaping Control Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Furthermore, as a limitation of the study, the open loop cascaded transfer function of both the filter and DC-DC isolated Ćuk converter have unstable Bode plots. This is the same as the open loop Bode plots of the transfer functions of Ćuk, boost, and SEPIC converters given in [60], [61], [62], [63]. Such unstable Bode plots are usual for power converters having nonminimum phase transfer functions.…”
Section: Discussionmentioning
confidence: 87%
See 1 more Smart Citation
“…Furthermore, as a limitation of the study, the open loop cascaded transfer function of both the filter and DC-DC isolated Ćuk converter have unstable Bode plots. This is the same as the open loop Bode plots of the transfer functions of Ćuk, boost, and SEPIC converters given in [60], [61], [62], [63]. Such unstable Bode plots are usual for power converters having nonminimum phase transfer functions.…”
Section: Discussionmentioning
confidence: 87%
“…By the Bode plot, gain margin is -35.1 dB and phase margin is -23.6°, meaning that the open loop DC-DC isolated Ćuk converter is unstable. Similar Bode plot responses of such a nonminimum phase system resulting in an unstable system are also obtained for Ćuk, boost, and SEPIC converters as in [60], [61], [62], [63]. For filter applications, the passive values of each filter type are calculated by using ( 25), ( 26), ( 27), ( 28), ( 29), ( 32), ( 33), (34) and they are given in Table 2.…”
Section: Lcl Trap Filtermentioning
confidence: 79%
“…Whereas in the switch-off mode, the energy stored in inductor 1 will flow to the capacitor 1. Because the diode is in forwarding conditions, the energy stored in inductor 2 will flow to the capacitor 2 through the diode [23]. Sepic converter topology can be seen in Figure 5.…”
Section: Figure 5 Topology Of Sepic Converter[22]mentioning
confidence: 99%
“…These transfer functions enable the identification of the converter's response to disturbances in each of its parameters or characteristics. Another representation is the switched model, which comprehensively describes the behavior of a converter and is derived from the operating modes (5,6,7,8,9,10,11,12,13,14). This model is useful for obtaining the converter's small-signal model (4,6,11,13,15,16), which is essential for designing linear controllers (17).…”
Section: Introductionmentioning
confidence: 99%
“…In converter control, output voltage regulation is commonly implemented (3,7,(11)(12)(13)15,16,21,22), to ensure that the converter maintains an approximately constant output voltage despite fluctuations in the input voltage supplying the converter or variations in connected load.…”
Section: Introductionmentioning
confidence: 99%