2020
DOI: 10.1371/journal.pone.0224447
|View full text |Cite
|
Sign up to set email alerts
|

Closed circuit xenon delivery for 72h in neonatal piglets following hypoxic insult using an ambient pressure automated control system: Development, technical evaluation and pulmonary effects

Abstract: Background Therapeutic hypothermia (TH) for 72h is the standard treatment following neonatal encephalopathy (NE). However, one-third do not benefit and adjunctive therapies are urgently needed. Xenon enhances neuroprotection with TH when administered at 50% concentration within 5hours of hypoxia in experimental studies. Delayed initiation (~10 hours of age) of 30% xenon for 24 hours during TH did not improve early adverse biomarkers in a clinical trial of Xenon+TH vs TH. After hypoxia-ischemia, excitotoxic inj… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 37 publications
0
1
0
Order By: Relevance
“…John et al developed an automated gas controller to monitor changes of breathing gas composition recirculated in a closed-circuit system and inject oxygen, air, or xenon as required to make the gas mixture achieve preset values ( Dingley et al, 2020 ). The automated controller successfully maintained the concentration of inhaled xenon close to 50% for 72–78 h at a xenon cost of $11.1/h in a model of hypoxic neonatal piglets ( Dingley et al, 2020 ). A previous study by John et al described a single-use closed-circuit Xe delivery system that proved both feasible and cost-efficient ( Chakkarapani et al, 2009 ).…”
Section: Xenonmentioning
confidence: 99%
“…John et al developed an automated gas controller to monitor changes of breathing gas composition recirculated in a closed-circuit system and inject oxygen, air, or xenon as required to make the gas mixture achieve preset values ( Dingley et al, 2020 ). The automated controller successfully maintained the concentration of inhaled xenon close to 50% for 72–78 h at a xenon cost of $11.1/h in a model of hypoxic neonatal piglets ( Dingley et al, 2020 ). A previous study by John et al described a single-use closed-circuit Xe delivery system that proved both feasible and cost-efficient ( Chakkarapani et al, 2009 ).…”
Section: Xenonmentioning
confidence: 99%